17. Once pinion-bevel gear crown backlash has been established, measure total preload T of bearings (pinion-bevel gear
crown system). Use a dynamometer whose cord is wound on the pinion ring nut with diameter D= 80 mm. The measured
value should be within following range:
- for T1 and T5 models T= (P+6.3) to (P+9.5) N
- for T2 models T= (P+7.0) to (P+11.0) N
- for T3 and T4 models T= (P+5.9) to (P+8.8) N
Warning: values for new bearings.
See: fig.17 and 18.
If bearings are not new, measured value should be starting value.
See: sec. D.21.1.1.