NOTE Clean the primary filter whenever choke indicator glows on dashboard.
1.0 GUIDELINES FOR DRY AIR CLEANER
• Clean the primary element after every 300 hrs of operation or when ever choke indicator
glows on dashboard.
• Replace primary element after 3 time cleaning or 900 hrs (whichever earlier).
• Gently pull primary element back and forth to take it out from housing.
• Clean primary filter element by blowing air (max. pressure) from inside.
• Safety cartridge not to be removed during cleaning of primary element. Safety cartridge to
be replaced after every three replacement of primary filter.
• Do not clean safety cartridge by compressed air.
• Use clean cloth to wipe sealing areas of primary filter.
• Ensure proper seating of filter into housing before latching the cover. Do not use latches on
the cover to force the filter into air cleaner that could cause damage to housing and will void
the warranty.
• Ensure proper seating of all rubber rings replace the damages ones.