    cristina16Aug 15, 2025
    What to do if the ITW GSE 6400 JetEx Tier 3 Portable Generator displays 'AIR FILTER CLOGGED'?
    • J
      Jennifer OwensAug 15, 2025
      If the ITW GSE Portable Generator's display indicates 'AIR FILTER CLOGGED', the solution is to change the air filter.
  • N
    Nicholas FriedmanAug 18, 2025
    How to prevent wet-stacking in ITW GSE Portable Generator?
    • M
      Melissa DavisAug 18, 2025
      To address wet-stacking in lightly loaded ITW GSE Portable Generator engines, connect the machine to a load bank after every 250 hours of use and run it under full rated load for one hour.
  • T
    Travis ThomasAug 21, 2025
    Why change crankcase oil in new ITW GSE 6400 JetEx Tier 3 Portable Generator?
    • E
      Elizabeth BlackAug 21, 2025
      New ITW GSE Portable Generator engines often release metal shavings more frequently, so it's important to change the crankcase oil.
  • E
    Erica GomezAug 25, 2025
    What to do if water pump weep hole is leaking in ITW GSE Portable Generator?
    • D
      David RodriguezAug 26, 2025
      If you observe a steady flow of coolant or oil from the water pump weep hole of your ITW GSE Portable Generator, replace the water pump with a new or rebuilt unit.
  • N
    Nathaniel FreemanAug 28, 2025
    How to clean corrosion from ITW GSE 6400 JetEx Tier 3 battery terminals?
    • C
      Charles McdonaldAug 28, 2025
      If you see corrosion on the battery terminals of your ITW GSE Portable Generator, disconnect the cables and clean the battery posts and connectors using a wire brush or a special battery post-cleaning tool.
  • D
    Daniel MaldonadoAug 31, 2025
    When to change oil filter element in ITW GSE Portable Generator?
    • G
      Gregory CaseySep 1, 2025
      The oil filter element of ITW GSE Portable Generator should be changed when you change the oil.
  • J
    Jacob SharpSep 4, 2025
    What to do if indicating lights don't work on ITW GSE Portable Generator?
    • B
      brenda01Sep 4, 2025
      If a light fails to operate on your ITW GSE Portable Generator, and power is present, replace the light fixture.
  • S
    Sarah FreemanSep 7, 2025
    When to replace air filter on ITW GSE 6400 JetEx Tier 3 Portable Generator?
    • T
      Tiffany DaySep 7, 2025
      When the 'Air Filter Clogged' warning appears on your ITW GSE Portable Generator, replace the air filter.
  • G
    Gloria MorganSep 10, 2025
    What to do if ITW GSE 6400 JetEx Tier 3 Portable Generator has leaks?
    • W
      Wendy WarnerSep 10, 2025
      If you find leaks on your ITW GSE Portable Generator, perform an overall inspection of the engine and maintenance may be required.

ITW GSE 6400 JetEx Tier 3 Specifications

General IconGeneral
Model6400 JetEx Tier 3
TypePortable Generator
Power Output90 kVA
Output Power72 kW
EmissionsTier 3 compliant