8
INSTALLATION
AIR CONDITIONER PLACEMENT
When selecting a place to install your air conditioner, consider the
following:
• Before powering on your air conditioner, let it stand upright for
at least two (2) hours.
• Keep your air conditioner upright whenever you move it.
• Do not install your air conditioner in bathrooms or other humid
environments.
EXHAUST HOSE ASSEMBLY
• If your air conditioner included a heat
preservation sleeve, place it over the exhaust
hose assembly before attaching it to the unit.
• Align the exhaust hose assembly with
the exhaust vent. Screw the exhaust hose
assembly counterclockwise to fasten into
place.
WINDOW SEALING PLATE ASSEMBLY
• Open your selected window halfway and mount the window
sealing plate. The window sealing plate can be installed
horizontally or vertically.
• Slide the window sealing plate assembly open until both ends
are in contact with the window frame. Set in place using the
clips.
INSTALLING THE AIR CONDITIONER
• Move your air conditioner with the exhaust hose assembly
installed toward the window. Be sure to leave at least 20" (50
cm) between your air conditioner and walls or surrounding
objects.
• Extend the exhaust hose assembly and snap the flat end of the
hose joints into the window sealing plate assembly.
NOTES: The flat end of the hose joints must be snapped into
place.
Make sure the exhaust hose does not have bends or angles
greater than 45 degrees. Keep the ventilation of the hose
unobstructed.
INSTALLATION