DIGISPENSE 3009 CONTROLLER MODULE, STYLE B Page 3-95
29 October, 2019 IVEK Corp. P03R017E
6 = Disable Recipe Save, Value Change, Recipe Get
Prime Direction & Start Stop - Front Panel
k2 k2,<value2> Returns the current Change Permission level.
<value2>
0 = Operator
1 = I/O Test
2 = Supervisor
3 = Keylock
k2,<value2> k2,<value2> Change Permission.
<value2>
Password for Desired Permission Level in command
Current Permission Level in response.
Maximum: 65,535
Minimum: 10
k3 k3,<value2> Returns the current Power Up Permission setting.
k3,<value2> k3,<value2> Sets the Power Up Permission configuration.
<value2>
0 = Operator
1 = Last at Power Off (default)
m => MODE
m or m0 m0,<value2> Returns the current mode.
m0,<value2> m0,<value2> Sets the operating mode.
<value2>:
0 = Disabled
2 = Dispense (default)
3 = Meter
m1,<value2> m1,<value2> Sets the Fluidic Mode.
<value2>:
0 = Disabled
1 = Prime (default)
6 = Agitate
n => RECIPE
n or n0 n0,<value2> Returns the current recipe number.
n0,<value2> n0,<value2> Get the specified recipe. <value2>: 1 - 32
n98,<value2> n98,<value2> Saves the current values to specified recipe if recipe number doesn't exist.
<value2>: 1 - 32
n99,<value2> n99,<value2> Saves the current values to specified recipe and overwrites any existing recipe.
<value2>:
q => READY/BUSY
q or q0 q0,<value2> Indicates the current state.
<value2>: 1 - 32
0 = Idle
1 = Priming
2 = Dispensing
3 = Metering
4 = Drawback Dwell
5 = Drawback
6 = Fault
7 = Referencing
8 = Initializing (on power-up)
9 = Pre-op dwelling
10 = Post-op dwelling
11 = Auto dwelling
12 = Isolating (agitate mode)
13 = Agitating