Installer Guide
AirModule E 9/15
6 720 809 156-00.1I
230V 1N~ / 400V 3N~
6 720 813 268(2014/10)

Table of Contents

Questions and Answers

  • J
    James NelsonAug 2, 2025
    What to do if my IVT AirModule E 15 Heat Pump shows DHW temperature sensor alarm TW1 error?
    • N
      nwilsonAug 2, 2025
      If your IVT Heat Pump displays a DHW temperature sensor alarm TW1 error, there are several potential solutions: * If no DHW system is installed, deactivate the DHW system in the service menu. * If the sensor is defective, replace it. * If screws or plugs are loose, tighten them. * If the sensor values are incorrect, replace the sensor. * If the sensor values are correct but the voltage is incorrect, replace the user interface.
  • M
    Michelle BeardAug 6, 2025
    What to do if I get Alarm E10 outside temperature sensor T0 error on my IVT AirModule E 15 Heat Pump?
    • J
      James FriedmanAug 7, 2025
      If you're getting an Alarm E10 indicating an issue with the outside temperature sensor T0 on your IVT Heat Pump, here's what you can do: * If there is no connection, correct the error. * Clean any corroded terminals in the outside temperature sensor assembly. * Replace the sensor if its values are incorrect. * If the sensor values are correct but the voltage is incorrect, replace the user interface.
  • P
    paige53Aug 11, 2025
    What to do if the cylinder 1 bottom temperature sensor is defect and Standby mode is active in IVT Heat Pump?
    • D
      David GriffinAug 11, 2025
      If the cylinder 1 bottom temperature sensor is defect and Standby mode is active in your IVT Heat Pump, try the following: * Modify the configuration. * Establish a correct connection. * Tighten screws or connections. * Replace the sensor if the values are incorrect. * If the sensor values are correct but the voltage is incorrect, the module should be replaced.
  • N
    nashamyAug 17, 2025
    How to fix a defect collector temperature sensor on IVT Heat Pump?
    • E
      egarciaAug 17, 2025
      To address a defect in the collector temperature sensor on your IVT Heat Pump: * Modify the configuration. * Establish a correct connection. * Replace the sensor if the values are incorrect. * If the sensor values are correct but the voltage is incorrect, the solar module should be replaced.
  • A
    angelaguerreroAug 22, 2025
    What to do if my IVT AirModule E 15 Heat Pump displays a warning that the last thermal disinfection failed?
    • R
      Ricky BrownAug 22, 2025
      If your IVT Heat Pump warns that the last thermal disinfection failed, consider the following: * Reduce continuous hot water consumption or change the time for thermal disinfection. * Ensure the DHW temperature sensor is correctly positioned. * Vent the system if required. * Correct any errors in the pipework. * If there are errors, replace the pump. * Check the DHW circulation pipes. * Replace the sensor if its values do not correspond with the diagram values.
  • E
    Emily CrawfordAug 27, 2025
    How to resolve two master user interfaces in IVT AirModule E 15 system?
    • J
      Jamie SmithAug 27, 2025
      To resolve the issue of having two master user interfaces in your IVT Heat Pump system, register the user interface as Master for heating circuit 1 to 4. You can configure CR10 as a remote control.

Summary

Key to Symbols and Safety Instructions

General Safety Instructions

Provides essential safety guidelines for installation and operation.

Technical Information

Measurements, Positioning Distance, and Pipe Connections

Installation

Connecting the Heat Pump Module to the Heat Pump

Guides on connecting the heat pump module to the outdoor heat pump unit.

Connecting the Heat Pump Module to the Heating System and Tap Water

Explains how to connect the heat pump module to the heating and DHW systems.

Heat Pump and Heat Pump Module Filling

Provides step-by-step instructions for filling and venting the system.

Electric Installation

Installer Module Circuit Diagram

Provides the circuit diagram for the installer module.

Power Supply Heat Pump and Heat Pump Module 9 kW 3 N~

Details the power supply connections for the 9 kW heat pump and module.

Heat Pump;Heat Pump Module Circuit Diagram

Shows the overall circuit diagram for the heat pump and module integration.

User Interface

Basic Principles of Operation

Using the Service Menu

Guides on navigating and operating the service menu for system adjustments.

Commissioning

General User Interface Commissioning

Covers the initial setup and configuration of the user interface.

System Commissioning via Configuration Wizard

Explains the process of configuring the system using the automated wizard.

Service Menu

Circuit 1 to 4 Menu

Enables detailed settings for each individual heating/cooling circuit.

Heat Pump Settings

Covers settings related to the heat pump's operation and performance.

Booster Heater Settings

Outlines configuration options for the booster heater's operation.

Settings for Heating;Cooling

Allows configuration of heating and cooling circuits, including system data.

DHW Settings

Diagnostics Menu

Troubleshooting

Heat Pump and Heat Pump Module Venting

Function Check

Maintenance

Connection for IP Module

Commissioning Protocol

IVT AirModule E 15 Specifications

General IconGeneral
CategoryHeat Pump
RefrigerantR410A
ModelAirModule E 15
Heating power15 kW
Operating Temperature Range Heating-20°C to 35°C