Installer Guide
AirModule E 9/15
6 720 809 156-00.1I
230V 1N~ / 400V 3N~
6 720 813 268(2014/10)

Table of Contents

Questions and Answers

  • J
    Joshua BrewerAug 7, 2025
    What to do if my IVT AirModule E 9 Heat Pump shows DHW temperature sensor alarm TW1 error?
    • S
      Steven RomeroAug 7, 2025
      If your IVT Heat Pump displays a DHW temperature sensor alarm TW1 error, there are several potential solutions: * If no DHW system is installed, deactivate the DHW system in the service menu. * If the sensor is defective, replace it. * If screws or plugs are loose, tighten them. * If the sensor values are incorrect, replace the sensor. * If the sensor values are correct but the voltage is incorrect, replace the user interface.
  • G
    gloverbrianAug 12, 2025
    What to do if I get Alarm E10 outside temperature sensor T0 error on my IVT AirModule E 9?
    • J
      Jonathan EllisAug 12, 2025
      If you're getting an Alarm E10 indicating an issue with the outside temperature sensor T0 on your IVT Heat Pump, here's what you can do: * If there is no connection, correct the error. * Clean any corroded terminals in the outside temperature sensor assembly. * Replace the sensor if its values are incorrect. * If the sensor values are correct but the voltage is incorrect, replace the user interface.
  • A
    adam95Aug 16, 2025
    What to do if the cylinder 1 bottom temperature sensor is defect and Standby mode is active in IVT AirModule E 9?
    • Y
      yhillAug 16, 2025
      If the cylinder 1 bottom temperature sensor is defect and Standby mode is active in your IVT Heat Pump, try the following: * Modify the configuration. * Establish a correct connection. * Tighten screws or connections. * Replace the sensor if the values are incorrect. * If the sensor values are correct but the voltage is incorrect, the module should be replaced.
  • K
    kevinjohnsonAug 21, 2025
    How to fix a defect collector temperature sensor on IVT Heat Pump?
    • A
      Ashley SimonAug 21, 2025
      To address a defect in the collector temperature sensor on your IVT Heat Pump: * Modify the configuration. * Establish a correct connection. * Replace the sensor if the values are incorrect. * If the sensor values are correct but the voltage is incorrect, the solar module should be replaced.
  • J
    Janet LittleAug 27, 2025
    What to do if my IVT AirModule E 9 displays a warning that the last thermal disinfection failed?
    • M
      morganfloresAug 27, 2025
      If your IVT Heat Pump warns that the last thermal disinfection failed, consider the following: * Reduce continuous hot water consumption or change the time for thermal disinfection. * Ensure the DHW temperature sensor is correctly positioned. * Vent the system if required. * Correct any errors in the pipework. * If there are errors, replace the pump. * Check the DHW circulation pipes. * Replace the sensor if its values do not correspond with the diagram values.
  • B
    Brandy HillAug 31, 2025
    How to resolve two master user interfaces in IVT Heat Pump system?
    • R
      Rodney WrightAug 31, 2025
      To resolve the issue of having two master user interfaces in your IVT Heat Pump system, register the user interface as Master for heating circuit 1 to 4. You can configure CR10 as a remote control.

Summary

Key to Symbols and Safety Instructions

General Safety Instructions

Provides essential safety guidelines for installers and users.

Technical Information

Heat Pump Module Specifications

Detailed electrical and mechanical data for the heat pump module.

Measurements, Positioning, and Pipe Connections

Installation

Checklist

A step-by-step checklist for the installation process.

Connect Module to Heat Pump

Details on connecting the heat pump module to the outdoor unit.

Connect Module to Heating;Tap Water

Connecting the module to the heating system and water supply.

Heat Pump and Module Filling

Procedure for filling and venting the system.

Electric Installation

Terminal Connections

Wiring terminals for different heat pump module variants.

Circuit Diagrams

Electrical schematics for 9 kW heat pump module configurations.

Circuit Diagram 15 kW

Electrical schematic for the 15 kW heat pump module configuration.

Power Supply 9 kW

Wiring diagram for the 9 kW heat pump and module power supply.

Power Supply 15 kW

Wiring diagram for the 15 kW heat pump and module power supply.

Installer Module Circuit Diagram

Wiring diagram for the installer module.

Heat Pump;Module Circuit Diagram

Overall system wiring diagram for heat pump and module.

User Interface

Important Usage Notices

Key warnings and notices for safe and effective operation.

Basic Principles of Operation

Using the Service Menu

Instructions on how to navigate and use the service menu.

Commissioning

General User Interface Commissioning

Steps for initial setup and configuration of the user interface.

System Commissioning via Configuration Wizard

Guide to the automated system setup and analysis process.

Commissioning Other Settings

Adjusting specific settings to meet customer requirements.

Service Menu

Heat Pump Settings

Configuration options for the heat pump's operational parameters.

Settings for Heating;Cooling

Parameters for configuring heating and cooling circuits.

DHW Settings

Configuration options for domestic hot water production.

Diagnostics Menu

Tools for system analysis and error checking.

Troubleshooting

Heat Pump and Heat Pump Module Venting

Function Check

Maintenance

Connection for IP Module

Commissioning Protocol

IVT AirModule E 9 Specifications