Do you have a question about the IVT C6 and is the answer not in the manual?
Explains warning symbols, signal words, and important information symbols.
Provides general safety advice for installation, commissioning, service, and maintenance.
Describes ground source heat pumps for C6-C11 and E6-E17 models.
Defines the permitted use of the heat pump in closed hot water heating systems.
Table showing different heat pump models and their heating outputs.
Locates the type plate and lists information found there.
Guidelines for safely transporting and storing the heat pump.
Instructions on placing the heat pump and considering ambient conditions.
Lists checks and requirements before commencing heat pump installation.
A step-by-step checklist for carrying out the heat pump installation.
Explains the CAN-BUS system and wiring precautions.
Provides essential safety precautions for handling circuit boards, including ESD protection.
Describes the different heating circuits and their control.
Explains control methods using outdoor or room sensors.
Details program control options for heating schedules.
Explains operating modes, including electrical additional heat.
Provides detailed dimensions and clearance requirements for C6-C11 models with diagrams.
Provides detailed dimensions and clearance requirements for E6-E11 models with diagrams.
Provides detailed dimensions and clearance requirements for E14-E17 models with diagrams.
Diagrams showing component parts for C6-C11 and E6-E17 models with labels.
Explanations of various system solutions and component references.
Pump performance curves for C6-C11 models.
Pump performance curves for E6-E17 models.
Information on collector pressure loss based on antifreeze concentration.
Details on installing and filling the collector system, including expansion vessels and antifreeze.
Instructions for installing the expansion tank, particle filter, heat carrier pump, and safety thermostat.
Guidance on selecting the optimal location for the heat pump, considering sound propagation.
Procedures for flushing the heating system to remove dirt and ensure water quality.
Instructions for installing a soft starter on different models, including EMC filter.
Guidance on installing various temperature sensors like flow, outdoor, hot water, and room sensors.
Critical steps for filling the heating system and checking for leaks.
Procedures for filling the collector system with antifreeze fluid, including using a filling station.
Steps to connect the heat pump, including removing panels and connecting cables.
Explains the function of the phase guard and error indications.
Notes on electrical connection requirements for screed drying.
Contains detailed wiring diagrams for circuit boards and complete connections.
Guidelines for making external connections and cable requirements.
Diagram and explanation of the control panel layout and its components.
Describes the function of the On/Off button on the control panel.
Explains the meaning of different status lamp indications on the control unit.
How to use the menu display to view information and change settings.
Instructions on navigating menus and changing settings using the control panel buttons.
Function of the Return button to go back to the previous menu.
How to use the Mode button to change operation type.
Using the Info button to access information on operating mode, temperature, etc.
How to access installer-level menus using a four-digit access code.
Procedure to quickly restart the compressor without waiting for the restart timer.
Lists available temperature sensors and their function.
Settings related to room temperature control, including general, circuit 1, and circuit 2/3 settings.
Settings for hot water production, peak times, modes, and circulation pumps.
Settings for holiday mode, including dates, temperatures, and blocking hot water.
Displays for generated energy and consumption of electric additional heat.
Configuration of various timers for heat pump operation, additional heat, and delays.
Settings for external inputs controlling functions like compressor, heating, and room temperature.
Installer-specific settings including anti-seizure, operating modes, groundwater, and compressor start delay.
Settings for additional heat functions, including general, electric, and program settings.
Safety settings for collector circuits, heat pump, and alarms.
General settings for date, time, display intensity, and language.
Information on alarms, including logs, history, indication, and buzzer settings.
Explanation of access levels for user and installer.
Procedure to reset all settings to the factory defaults.
Overview of the alarms section.
Explains the function of the control unit and room sensor alarm lamps.
How alarms and warnings are displayed and logged.
Functionality and blocking of the alarm buzzer.
How to acknowledge alarms to clear them from the display.
Explanation of the alarm timer and its effect on additional heat.
Classification of alarms and warnings based on severity and type.
How alarm information is presented in the display window.
Detailed descriptions of specific alarm functions and their triggers.
Procedure to restore default factory settings for customer and installer levels.
Table listing factory default values for various settings by access level.
Safety precautions and checks for the refrigerant circuit.
Checking and topping up the collector circuit filling pressure.
Guidance on setting and checking the heating system operating pressure.
How to check operating temperatures and adjust circulation pump speeds.