33
Preset parameters
To machine off, press the button and turn the machine.
When the display shows the PrS, release the button and shut down and restart the machine.
Reset all values to the table above, for the desired temperature refer to the diagram ”temperature
range”
Default settings TermoPid
EUROPA AMERICA
Parametri Display Parametri Display
F.01 °C F.01 °F
F.02 5-7 F.02 7
P
1.3
P 1.3
I
006
I 006
D
1.5
D 1.5
T1 93 T1 200
T2 123 (min 121- max 128) T2 255 (min 248- max 262)
T3
80
T3
176
E1 10 E1 18
E2 0 E2 0
E3
0
E3
0
Temperatura range
CELSIUS FAHRENHEIT BAR INFORMATION
120 248 1 turn the machine on and wait about 14-15 minutes to
bring the temperature from 0 to 120 degrees
121 249.8 1.1
122 251.6 1.15 T1 = coffee boiler
123 253.4 1.2 T2 = boiler water and steam
124 255.2 1.3
125 257 1.35
126 258.8 1.4
127 260.6 1.45
128 262.4 1.5 Ceiling
Alarms
In case of malfunction, the display shows the following warning messages:
Channel 1 disconnected (A1), channel 1 short-circuit (A2), Channel 2 disconnected (A3), channel
2 short-circuit (A4).