12
A2: channel 1 in short circuit
If the above malfunction occurs, contact technical support directly.
8.2 AUDIBLE ALARMS FROM BUZZER UNIT
An alarm condition is signalled by an audible alarm. The buzzer will
automatically produce an audible signal in one of the following cases.
Alarm 1: in case of lack of water in the reservoir, the buzzer will automatically
produce an audible signal.
Alarm 2: following a continuous pump activity for a duration of more than 60
sec. the buzzer will automatically produce an audible signal.
Alarm 3: in case of malfunction of the pump the buzzer will automatically
produce an audible signal.
N.B. To know how to proceed in the event of an alarm, consult Par. 14.
9. DISPENSING
9.1 PREPARING ESPRESSO COFFEE
Manually lifting the coffee dispenser lever (fig. 6, tab. 1) starts the dispensing
stage. Lowering the lever, dispensing is interrupted.
For every cup of coffee add 6-8 grams of ground coffee in the filter holder
and press it down. Insert the filter holder under the unit by rotating it from left
to right until it is tightened.
Place one or two cups under the filter holder spout and raise the lever (it is
recommended to warm the cups). The coffee will now begin dispensing, first in
drops, then it will flow out thick like hot chocolate, and the display will show
the time in seconds. When the cup has been filled with the desired amount of
coffee, lower the lever.