22
Pull out the rubber tube downwards, then wash thoroughly. Check that the hole in the nozzle
is not blocked, if necessary unblock them with a pin.
• Revolve the rubber tube onto the nozzle.
Cup stand, drip tray
Empty the drip tray regularly, you’ll know when it is full, the red float in the drip tray (4,
schedule 1) will rise and become visible in the hole on the cup stand. Wash then dry.
Cleaning Mineral Deposits
1. To make sure your coffee maker is operating efficiently, internal piping is cleanly and
the peak flavor of coffee, you should clean away the mineral deposits left every 2-3 months.
2. Fill the tank with water and descaler to the MAX level (the scale of water and descaler is
4:1; the detail refers to the instruction of descaler. Please use “household descaler" and follow
the instructions of the descaler for cleaning appliances.
3. According to the program of pre-heating, put the metal funnel (no coffee powder in it) and
carafe (jug) in place. Brewing water per “PRE-HEATING”.
4. Press the “ON/OFF for Coffee” (1, scedule 1) , the blue light blinks until it is
stabilized, the appliance is heated. Then press the “coffee” switch (2, scedule 1) , when
there is water flowing out and close the pump.
5. When the blue lamp is illuminated, it shows the heating is finished, press the “coffee” switch
and make two cups of coffee. Then close the pump (press the “coffee” switch and
wait for 5s).
6. Press the steam switch, waiting until the blue indicator is illuminated permanently. Make
steam for 2min, then turn the steam control knob to anticlockwise revolution. Press the steam
switch to stop the unit immediately; make the descalers deposit in the unit at least 15 minutes.
7. Restart the unit and repeat the steps of 4-6 at least 3 times.
8. Then Press the “ON/OFF for Coffee” (1, scedule 1) , when the blue lamp is
illuminated permanently, press the “coffee” to brew until no descaler is left.
9. Then brewing coffee (no coffee powder) with tap water in the MAX level, repeat the steps of
4-6 for 3 times (it is not necessary to wait for 15 minutes in step of 6), then brewing until no
water is left in the tank.
10. Repeat the step of 9 at least 3 times to make sure the piping is cleanly.
Troubleshooting
• If you have a problem, you may find the solution in the table below. If the table does not
provide the solution to your problem, please contact with the nearest authorized BENRUBI
service agent for examination, repair or adjustment.
Symptom Cause Corrections
Carafe leakage water or
water leaks out from lid of
carafe
The carafe is not located
properly
Let centreline of carafe aligns
with leakage opening of brew
basket well.