Specifications
FAA Approved
Indicator TSO & STC
Fuel Flow Option STC
Display Size:
3 1/8 in panel mount
3.5 in. sq., 7.5 in. deep
Common Mode Range:
+ 4v, rejection > 80db
Analog Thermocouples
Response curve: All Linearized.
Resolution: 1.0
o
F
Accuracy: + 1.0
o
F
Calibration: type K (J CHT avail.)
Operating Temperature Range:
-40 to 195
o
F
Temperature Range:
EGT bar graph: variable
EGT, TIT digital: -40 to 2500
o
F
CHT, OAT, IAT: -40 to 800
o
F
Analog input channels:
12 Exhaust Gas Temperature (EGT)
12 Cylinder Head Temperature (CHT)
2 Turbine Inlet Temperature (TIT)
2 additional channels
(either OIL, CRB or second TIT)
1 Outside Air Temperature (OAT)
1 System Bus Voltage (BAT)
Resolution and Display Range (Fuel Flow Option)
display maximum display value resolution
K factor range:
5,000 to 99,990 10
Fuel flow:
Accuracy (8 to 60 GPH) 1 %
140.0 GPH at K factor 85,000 0.1 GPH
410.0 GPH at K factor 29,000 0.1 GPH
820 PPH at K factor 85,000 1 PPH
2400 PPH at K factor 29,000 1 PPH
560 LPH at K factor 85,000 1 LPH
1640 LPH at K factor 29,000 1 LPH
372 KPH at K factor 85,000 1 KPH
1088 KPH at K factor 29,000 1 KPH
Fuel Remaining:
999.9 Gal 0.1 Gal
999 Lbs., L, or Kg 1 Lb., L, or Kg
Fuel Used:
999.9 Gal. 0.1 Gal
9999 Lbs., L, or Kg 1 Lb., L, or Kg
Time to Empty:
50 hours 1 minute
Long Term Memory