CONFIDENTIAL PROJECT NAME | date 项目名称 | 日期 26
Operation Instruction technical parameter
Electro
nic
thread
slack
210
0
0
12
3
45
6
thread slack electromagnet timing
selection:
0
[LS] After set angle then make thread slack movement , until upper
needle position delay again
[T2] to the setting time
1
[LS] After set angle then make thread slack movement ,until [LE] set
angle.
2
[LS] After set angle then make thread slack movement , delay [T2] to
setting time
3:After down needle position signal delay
[T1] setting time to slack
thread , until delay to
[T2] setting time.
4:After upper needle position signal delay
[T1] setting time to slack
thread , until delay to
[T2] setting time
5:After down needle position signal start to thread slack until up needle
position stop, then delay [T1] setting time
then make [T2] setting thread
slack time
6:[LS]
After set angle then make thread slack movement , until upper need
stop. Then delay
[T1] setting time then make
[T2] setting thread slack time
P+ power
button
211
35
5-359
thread slack electromagnet
starting angle LSrelative
to down needle angle
212
300
10-359
thread slack electromagnet
ending angle LErelative to down needle angle
bigger
than LS
213
1
1-999
thread slack
electromagnet starting delay time T1ms
214
10
1999
thread slack electromagnet upper needle position delay time T2
ms
265
5
030
0
forbid to output 5: thread slack electromagnet