11
Stop time testing
P55
A 项测试
A Testing
0 - 2 0
0:关闭 1:开启 2: 休眠
0off 1on 2: dormancy
P56
B 项测试
B Testing
0 - 1 0
0:关闭 1:开启 (电磁铁测试)
0off 1on (electromagnet testing)
P57
压脚保护开关
Presser foot safety switch
0 - 1 1
0:关闭 1:开启
00ff 1on
P58
缝台保护开关
Sewing plate safety switch
0 - 1 1
0:关闭 1:开启
00ff 1on
P59
针杆护罩保护开关
Needle bar cover safety switch
0 - 1 1
0:关闭 1:开启
00ff 1on
P60 - - -
P61
休眠时间 Sleeping time
1 - 250 30
分钟 Unit: minutes
P62
面板按键锁定
Panel button lock
0 - 1 0
0:不锁定 1:锁定 0unlock 1lock
(面板锁定后长按剪线键解除锁定)
After the panel is locked, press the clipping button
to unlock it
P63
降速开关
Slow down speed button
0 - 1 0
P64
降速针数
Stitch number of slow down
speed
1- 800 4
P65
降速速度
The speed of slowing down
500 - 7000 3500 RPM
P66
前传感器档位调节
Adjusting gear of front sensor
1 - 180 --
参数值越大,传感器电压值越大
The greater the parameter values.The greater the
voltage value of the sensor
P67
后传感器档位调节
Adjusting gear of back sensor
1 - 180 --
参数值越大,传感器电压值越大
The greater the parameter values,The greater the
voltage value of the sensor
P68
防切布传感器档位调节
Adjusting gear of sensor for
anti cutting the cloth
1 - 180 --
参数值越大,传感器电压值越大
The greater the parameter values,
The greater the voltage value of the sensor
P69
计件数计数单位
Unit number counting
1 - 50 10
执行设置剪线次数,计件数加 1
Setting per unit trimmer number,piece count plus1
P70
计件数总数设定
Total counting setting
1 - 9999 100
P71
计件数计数模式
Counting mode
0 - 5 0
0关闭;1:升序循环计数;2降序循环计数;
3:升序计满报警;4:降序计满报警;
5:清除计满报警
0off1ascending cycle count2descending
cycle count3ascending full alarm4descending
full alarm5remove full alarm
P72
强制后剪线延迟针数
The stitches number of
constraint back trimmer
0 - 80 36
布料前剪线后离开前、后传感器且未遮住第三传
感器经过设定针数后执行后剪线。
Adjust the back trimmer function even the fabric
does not cover the anti-cutting sensor, can adjust
the stitches number before the trimmer function
active.
P73
出厂默认转速参数
Default Speed Parameters
0 - 1 0
0:四线机型默认转速 P01=6000 P03 =5500
0Default speed of four thread model
1:五线机型默认转速 P01=5000 P03 =5000
1Default speed of five thread model
系统员参数(P+上键,设置三位密码进入“111”)
System member parameters (P + up button, set three passwords into "111")
P75
转接板报错使能
Transfer board error reporting
enablement
0 - 1 1
0:关闭;1:打开转接板检测功能;
0off;1Open the switch board detection function