EasyManua.ls Logo

Jacuzzi J-SN180W - Maintenance Procedures; Pressure Relief Valve and Flame Inspection; Winterizing Procedures for Gas, Water, and Electric; Vent Termination Winterization

Jacuzzi J-SN180W
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JacuzziSignatureWaterHeatersJS180/JS199 37
Tesngthepressurereliefvalveshouldonlybe
performedbyalicensedprofessional.Scaldinghot
watermaybereleasedunderpressure.
WARNING
PressureReliefValve:
Operatethevalvemanuallyonceayear.Indoingso,
itwillbenecessarytotakeprecauonswithregardto
thedischargeofpotenallyscaldinghotwaterunder
pressure.Ensuredischargehasaplacetoow.
Contactwithyourbodyorotherpropertymaycause
damageorharm.
VisualInspeconofFlame
Verifyproperoperaonaerservicing.
Theburnermustameevenlyovertheenresurface
whenoperangcorrectly.Theamemustburnwith
aclear,blue,stableame.Seethepartsbreakdown
oftheburnerforthelocaonoftheviewports.
Theamepa
ernshouldbeasshowninthegures
below.
FreezeProtecon
Makesurethatincaseoffreezingweatherthatthe
waterheateranditswaterlinesareadequately
protectedtopreventfreezing.Damagedueto
freezingisnotcoveredbythewarranty. Refertothe
secononFreezeProtecon.
Winterizing
Theserecommendaonsareintendedtosuggest
pracceswhichareeecveforwinterizingthewater
heater.Theyshouldbeusedasaguideonly.No
liabilityisassumedforanyissuesresulngfromthe
useofthisinformaon.
GAS
Shutoffthegastothewater
heater.Itisgenerally
preferabletoshutoffthegasservicetotheenre
locaonifgasisnotgoingtobeused.
WATER
Shutoffthecoldwatersupplytothewaterheater.It
isgenerallypreferabletoshutoffthewatertothe
enreloca
onifwaterisnotgoingtobeused.
Drainthewaterheaterbyopeningthedrainvalveson
thecoldwaterlineandhotwaterline.
Openseveralhotwatertapsandremovethelter
assemblyatthewaterinletinordertoallow roomfor
expansionincase
thereiswaterinthelinesthat
freeze.
ELECTRIC
Disconnectthepowersupplybyeitherunpluggingthe
electricalcordorbyturningoffthecircuitbreakerto
thewaterheatertopreventpotenaldamagefrom
irregularpowersurgesorinterrupons.
VENTTERMINATION
Placeacoverovertheventtermina
on(intakeand
exhaust)ifitcanbesafelyaccessed.Thecovershould
beeasytoapplyandremove.Thiswill prevent
debris,leaves,andsmallanimalsfromenteringthe
venngandwaterheaterwhichcoul dcauseairow
issuesuponreturntoservice.

Related product manuals