32
Heat Mode
Ready vs. Rest / Circulaon Mode / Ready-in-Rest Mode
Heat Mode—Ready vs. Rest
In order for the swim spa to heat, a pump needs to circulate water through the heater(s). The
pump that performs this funcon is known as the “heater pump”.
The heater pump can be either a 2-speed pump (Pump 1) or a circulaon pump.
If the heater pump is a 2-Speed pump 1, Ready Mode will circulate water every 1/2 hour, us-
ing Pump 1 Low, in order to maintain a constant water temperature, heat is needed, and re-
fresh the temperature display. This is known as “polling”.
Rest Mode will only allow heang during programmed filter cycles. Since polling does not oc-
cur, the temperature display may not show a current temperature unl the heater pump has
been running for a minute or two.
When the heater pump has come on automacally (for example for heang) you can switch
between low speed and high speed but you cannot turn the heater pump off.
Circulaon Mode
If the swim spa is configured for 24HR circulaon, the heater pump generally runs connu-
ously. Since the heater pump is always running, the swim spa will maintain set temperature
and heat as needed in Ready Mode, without polling.
In Rest Mode, the swim spa will only heat to set temperature during programmed filter mes,
even though the water is being filtered constantly when in 24HR circulaon mode.
Ready-in-Rest Mode
Ready in Rest Mode appears in the display if the swim spa is in Rest Mode and the Jets 1
Buon is pressed. When the heater pump has come on automacally (for example for
heang) you can switch between low speed and high speed but cannot turn the heater pump
off. Aer 1 hour, the System will revert to Rest Mode. This mode can also be reset by selecng
the Heat Mode line on the Screen shown on the previous page.