8. FURTHER GUIDANCE
Water Treatment
It is important that the water in the system is
treated to maintain system eciency and provide
longevity for the heating element and associated
system components.
Consideration should be given to power flushing
(cleaning the system), treatment with inhibitor, system
filtration and limescale prevention.
The water should be checked annually.
Failure to maintain good water quality will result in
the product guarantee being null and void.
Balancing
Please balance the heating system ensuring correct
water flow to each radiator and even heat distribution
to each room.
Air Vent
Bleed air from radiator using the
extended air vent, ensuring that
the clear plastic tube is attached
to the spigot to allow for easy
collection of the water. Bleeding
is achieved using a flat blade
screw driver.