Do you have a question about the Jaga STRADA and is the answer not in the manual?
Material | Steel |
---|---|
Operating Pressure | 10 bar |
Installation | Wall-mounted |
Control | Thermostatic |
Finish | Powder coated |
Connections | 1/2" |
Mounting | Brackets included |
Ensure optimal placement for heat distribution and a sound wall structure.
Details radiator dimensions and notes on flow/return connection options.
Instructions on removing protective covering from the heating element connection.
Guidance on connecting the air vent to the heating element's top connection.
Correctly attaching radiator brackets, ensuring proper orientation.
Drilling 8mm holes at marked centres for secure wall mounting.
Inserting wall plugs and screws, leaving 10mm protruding for bracket attachment.
Securing the heating element assembly to the wall using provided fixings.
Moderately tightening the air vent to its designated 1/8th connection.
Fitting the radiator valves, following specific options and illustrations.
Specifics on connecting valves to floor or wall based on radiator type.
Ensuring correct operation by connecting the thermostatic valve to flow and lockshield to return.
Installing the blanking plug into the unused connection on the radiator.
Completing installation and pressure testing the system up to a maximum of 10 bar.
Post-testing requirement to clean and flush the system according to standards.
Advice against leaving the radiator empty for extended periods after flushing.
Hooking the casing onto the bottom bracket and securing it.
Locating the grille into the front panel and fixing the back bar.
Fitting the TRV head to its maximum setting, following specific instructions.
Inserting the first half-moon decorative clip onto the radiator.
Inserting the second half-moon decorative clip.
Using a blanking plate on the opposite side of the casing.
Gently tapping a wedge with a rubber mallet to remove the top grille.
Removing the back bar from the radiator grille assembly.
Replacing the top grille onto the radiator assembly.
Replacing the back bar into position on the radiator.
Securing the back bar by tapping gently with a rubber mallet.
Instructions for using the arthritic aid with Jaga White TRV heads.
Emphasizes treating water for system efficiency and component longevity.
Balancing the heating system for correct water flow and even heat distribution.
How to bleed air from the radiator using the extended air vent and a flat blade screwdriver.
Diagnosing issues like TRV faults, closed valves, or system imbalance.
Checking boiler, pump, controls, water flow temperature, and system balancing.
Ensuring adequate airflow and removing protective coverings.
Checking radiator sizing for the room and addressing perception of heat.
Resolving TRV chattering by ensuring correct flow and return connections.