EasyManuals Logo
Home>Jandy>Swimming Pool Filter>DEV48

Jandy DEV48 User Manual

Jandy DEV48
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Page 12
WARNING
Working with muriatic acid can be dangerous. When
cleaning lter grids, always wear rubber gloves and
eye protection. Add acid to water, do not add water
to acid. Splashing or spilling acid can cause severe
personal injury
and/or property damage.
5. See Section 5.2 for reassembly of the lter tank
and lter grids.
6.5 Cleaning Filter Grids with Muriatic Acid
1. Check with your local pool store or service
company to see if they offer lter grid de-scaling
services.
2. Stiffening of the lter grid fabric is caused by
mineral deposit buildup. It is usually due to
deposits of either magnesium, calcium, alkalines
or carbonates. Removal of these deposits may
be accomplished by soaking the lter grids in a
plastic tub or pail with six (6) parts water to one
(1) part hydrochloric acid (muriatic acid).
3. Wear rubber gloves and eye protection when
mixing the solution, and handling or rinsing the
lter grids.
4. Soak for at least four (4) hours.
5. Rinse the lter grids thoroughly with water.
6. See Sections 5.1 and 5.2 for reassembly of the
lter tank and lter grids.
Section 7. Winterizing
1. Turn off the pump and circuit breakers.
2. Open the air release valve and move the diverter
valve handle to a position between two (2) ports.
This will allow air to ow to all ports.
3. Remove the drain plug at the base of the lter to
ensure that the tank is empty. Store the drain plug
and seal it in a safe place. Do not reinstall until
next season at start-up.
4. Drain system piping of all water.
5. Cover the system with a tarpaulin or plastic sheet
to protect it from the weather.
Section 8. Troubleshooting
1. For a list of common problems and solutions, see
the Troubleshooting Guide on the following page.
2. Zodiac recommends that you call a service
technician to do any work on the lter/pump
system. For technical assistance, contact our
Technical Support Department at 1.800.822.7933

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy DEV48 and is the answer not in the manual?

Jandy DEV48 Specifications

General IconGeneral
BrandJandy
ModelDEV48
CategorySwimming Pool Filter
LanguageEnglish