27
5
Name
Setting Range
Setting
increments
Minimum
Initial
value
Parameters
P100
Digitalfrequency
setting
0.00~Maximum
0.1 0.0
Frequencysetting
selection
0:Digitalfiequency
setting (P100)
1:Analogvoltage
(0~
10VDC)
2:Analogcurrent
(0~20mADC)
3:Settingdial
(Operation panel)
4UP/DOWNfrequency
setting
5:RS485communication
frequency
setting
P101
1 3
Startsignalselection
0:Operationpanel
(FWD/REV/
STOP)
1:I/Oterminal
2:Communication
(RS485)
P102
1
0
stop”keylock
operationselection
0:“Stop”keylock
modeinvalid
1:
Stop”keylockmode
valid
1 1
P103
0:Reverserotation
disallowed
1:Reverserotation
allowed
Reverserotation
prevention
selection
P104
1 1
Minimum~400.00Hz
Maximum
frequency
0.1 50.0
P105
P106
Minimum
frequency
0.00
~Maximum
0.1 0.00
BasicFunction
P107
Accelerationtime1
0~999.9s
0.1
Depends
on
models
P108
Decelerationtime1
0~999.9s
0.1
P109
V/Fmaximumvoltage
V/Fintermediatevoltage
~ 500.0V
0.1
Chapter 5 Function Parameters Table
FC100 Series User Manaul

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Janson Controls FC100-4T-4.0G and is the answer not in the manual?

Janson Controls FC100-4T-4.0G Specifications

General IconGeneral
BrandJanson Controls
ModelFC100-4T-4.0G
CategoryController
LanguageEnglish

Related product manuals