INSTALLATION INSTRUCTIONS
Ensure the drive unit is engaged for normal
“auto” operation and the power is ON.
1. Press and hold LEARN button until three
BEEP sounds are heard
The logic controller will learn the OPEN position
FIRST
2. Press and hold the UP button until the door
moves to the required OPEN position
Small adjustments may be made by momentary pressing of the UP
or DOWN button to move the door to the required position
Do not allow the bottom bar of the door to contact the head stops
3. When the OPEN position is achieved – press
the LEARN button once – two BEEP sounds will
confirm the setting.
The logic controller is now ready to learn the
CLOSED position.
4. Press and hold the DOWN button until the
door moves to the required CLOSED position
Small adjustments may be made by momentary pressing of the UP
or DOWN button to move the door to the required position
5. When the CLOSED position is achieved –
press the LEARN button once – two BEEP
sounds will confirm the CLOSED setting— the
operator will perform an automatic check of both
settings
1 “learn”
2 “open position”
5 “confirm settings”
STEP 7.
“Setting the electronic limits”
4 “closed position”
3 “confirm & learn”