MCP - Inputs
Page 33 of 80
2.3 INPUTS
2.3.1 Steering Mode Selection
Description
This connection provides the common to and the inputs from a series of
momentary action push buttons. There are two dedicated dimmer inputs
to provide dim up and dim down functions for the indicator illumination as
well as 10 configurable steering mode selection inputs. Through the DSC
configuration set up, functions are assigned to each of the 10 configurable
inputs while unused inputs are turned off. Any of the configurable inputs
can be assigned functions for steering mode, rudder speed control and
station transfer.
Specifications
Contact Format ............................ Momentary Action, Normally Open
Signal Format .............................. Sourcing 5V (COMM) from MCP
Connector ....................................3.81mm pitch pluggable screw terminals
Installation
Number of conductors required will depend on the number of mode
selection buttons used.
Mode selection buttons are to be momentary action, normally open
contacts.
Commissioning
Each mode selection button is assigned a specific function through the
DSC Setup Software in the SCP Configuration Window (see section 4.1.1
)
or through the DSC’s keypad entry SCP menu (see section 4.2.2
).
Doc No.: MAN01504, 20-02-06 DSC 100 & MCP 100 Manual