7
6
2.0 SPECIFICATIONS
EN
REF FEATURES TECHNICAL SPECIFICATIONS
2.1
Refrigerants EPA Certied to ARI 740-98 for refrigerants, HFC,HCFC and CFC
2.2
Safety Designed to meet UL1963, AS standards & EU equivalents
2.3
Power 220/240 VAC/50Hz, 110-115 VAC/50Hz
2.4
Compressor 3/4 HP oil less, BLDC motor drive
2.5
Cooling Fan direct
2.6
Protection High pressure switch cuto at 3850 Kpa
Compressor protected by brushless DC drive circuit
2.7
Pressure Max low side design pressure 2600Kpa
Max high side design pressure 3800Kpa
2.8
Temperature Operating range 10°C to 40°C
2.9
Case Injection moulded glass reinforced high impact
2.10
Size L 320mm X W 220mm X H 260mm
2.11
Weight 8.5 Kg
REFRIGERANT
LIQUID RATE
(Kg/Min) (Kg/Hr)
VAPOUR RATE
(Kg/Min) (Kg/Hr)
PUSH/PULL
RATE
(Kg/Min) (Kg/Hr)
RESIDUAL
TRAPPED
REFRIGERANT
(Kg)
R22 2.30/138 0.31/18.6 7.10/426 <0.1
R134-a 2.00/120 0.25/15 5.80/348 <0.1
R410A 1.65/99 0.30/18 7.00/420 <0.1