6
2.0 SPECIFICATIONS
EN
REF FEATURES TECHNICAL SPECIFICATIONS
2.1
Refrigerants EPA Certied to ARI 740-98 for refrigerants, HFC,HCFC and CFC
2.2
Safety Designed to meet UL1963, AS standards & EU equivalents
2.3
Power 220/240 VAC/50Hz, 110-115 VAC/50Hz
2.4
Compressor 3/4 HP oil less, BLDC motor drive
2.5
Cooling Fan direct
2.6
Protection High pressure switch cuto at 3850 Kpa
Compressor protected by brushless DC drive circuit
2.7
Pressure Max low side design pressure 2600Kpa
Max high side design pressure 3800Kpa
2.8
Temperature Operating range 10°C to 40°C
2.9
Case Injection moulded glass reinforced high impact
2.10
Size L 320mm X W 220mm X H 260mm
2.11
Weight 8.5 Kg
REFRIGERANT
LIQUID RATE
(Kg/Min) (Kg/Hr)
VAPOUR RATE
(Kg/Min) (Kg/Hr)
PUSH/PULL
RATE
(Kg/Min) (Kg/Hr)
RESIDUAL
TRAPPED
REFRIGERANT
(Kg)
R22 2.30/138 0.31/18.6 7.10/426 <0.1
R134-a 2.00/120 0.25/15 5.80/348 <0.1
R410A 1.65/99 0.30/18 7.00/420 <0.1
XTRULTRA-2 A5 safety-operation-manual.indd 6 01/02/2018 15:42