22

the vehicle was constructed (for more information, refer to Sec. 2, Formaldehyde).


1. If CO gas reaches unsafe levels, alarm enters CO alarm state.
2. Horn sounds with (4) rapid chirps, then 4-second pause and red LED ashes rapidly.
3. Operate the SILENCE/TEST button to silence the alarm for 5 minutes.
4. The original alarm state resumes after 5 minutes if CO levels still exceed safe levels.
5. Immediately move to fresh air (outdoors or by an open door or window).
6. Call 911.
7. Do not re-enter the premises or move away from the open door or window until the
emergency service responders have arrived, the premises have been aired out, and your
alarm remains in its normal condition.

1. If propane gas exceeds 10% of the lower explosive limit for more than 30 seconds,
alarm enters propane alarm state.
2. Horn sounds with constant beeps and the red LED will be ON.
3. Turn o all propane appliances and gas valve at LP tanks.
4. Ventilate the RV – open doors and windows
5. Alarm can be silenced for 5 minutes by pressing SILENCE/TEST button.
6. Red LED will ash each second while alarm is silenced.
7. Original alarm state resumes after 5 minutes if propane levels still exceed the safe
levels.
8. Do not touch any electrical switch in or near the recreation vehicle.
9. Do not start vehicle’s engine or generator.
If your alarm reactivates within a 24-hour period, repeat steps 1-4 and call a qualied appli-
ance technician to investigate for sources of carbon monoxide from fuel burning equipment
and appliances, and inspect for proper operation of this equipment. Make sure that motor
vehicle(s) are not, and have not been, operating in an attached garage or adjacent to the
recreation vehicle.
If problems are identied during this inspection, have the alarm serviced immediately. Note
any combustion equipment not inspected by the technician and consult the manufacturers
instructions or contact the manufacturer directly for more information about carbon monox-
ide safety and this alarm.
Actuation of this detector indicates the presence of carbon monoxide
which can kill you.
Never turn the 12-volt battery disconnect control to the o position and
disconnect the battery cable to silence an alarm. The alarm will automati-
cally sense when the level of carbon monoxide in the air reaches below
dangerous levels. You should stay outside the vehicle in fresh air until
the alarm is silenced. When the alarm sounds, do not stand too close to
the alarm. The sound produced by the alarm is loud (85db) because it is
designed to wake a person in an emergency. Prolonged exposure to the
alarm at a close distance may be harmful to your hearing.



Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jayco JAY FLIGHT 2023 and is the answer not in the manual?

Jayco JAY FLIGHT 2023 Specifications

General IconGeneral
Year2023
ManufacturerJayco
ModelJAY FLIGHT
Fuel TypeN/A (Travel Trailer)
EngineN/A (Travel Trailer)
TransmissionN/A (Travel Trailer)
Width8 ft
Sleeping CapacityVaries by model (e.g., 2 to 10 people)
Air ConditioningYes
HeatingYes
GeneratorOptional
AwningYes
Entertainment SystemYes
KitchenYes
BathroomYes

Related product manuals