85

Connect to city water to supply water to RV xtures
Winterize plumbing lines and xtures
Bypass the hot water heater when winterizing to avoid damage to the water heater
Rinse the black tank to help control odors and prevent waste buildup
Rinse o items outside the unit with hot/cold faucet
Connect up to (3) coax lines with satellite, cable and auxiliary
The city water connection inlet is located in the Uni-Dock utility center.

: Receives water from water inlet on the front panel.
Sideways: Water goes to pump inlet.
Downward: Water goes into the blue handled diverter.
 : Receives water from the white handle valve/water inlet on the front
panel.
Sideways: Water goes to or comes from the fresh water tank.
Downward: Water goes out to the xtures (cold).
: Receives water from the cold water supply.
Sideways: Water goes to hot water xtures  going through hot water
heater.
Upwards: Water goes to hot water heater.
: Receives water from the pump.
Sideways: Water goes to fresh water tank.
Upwards: Water goes to xtures.

The following information details the functions of the utility center water valves as dis-
played on the valve operation label.

1. Connect the fresh water hose to the City water connection inlet on the utility center.
2. Set the color coded valves to POWER FILL TANK setting:




3. Connect the other end of the hose to a pressurized fresh water source (faucet or spigot).
4. Turn the pressurized water source ON, the tank should begin lling.
A check valve is located inside the city water connection inlet on the utility
center. NEVER        
 It will cause irreparable damage to the
valve function and the inlet will leak water.

