51
2. Open the “fresh tank drain” valve.
3. Open the low point drain valves. There is a label to indicate where the drains are lo-
cated.
4. Turn ON the water pump and allow it to run until water no longer ows.
Some water may remain in the lines. If the recreation vehicle will be exposed to cold tem-
peratures, it must be winterized to protect the plumbing system and components. Damage
to the water lines and components due to freezing is not covered by warranty. Refer to the
Sanitizing/Winterizing the Plumbing System for details
Utility Center (P4)
 allows you to perform the fol-
lowing functions:
Power ll the fresh water tank for remote or dry
camping
Use the pump to supply water to xtures from the
fresh water tank
Use the pump to siphon ll or sanitize the fresh wa-
ter tank from a bucket
Connect to city water at the camp site to supply wa-
ter to RV xtures
Winterize the plumbing lines and xtures
Rinse o items outside the unit with a hot/cold fau-
cet

Use a non-toxic drinking water hose dedicated only to supplying fresh water. To prevent
contamination, keep the non-toxic drinking water hose from coming into contact with the
ground. Install the city water connection inlet cap when the fresh water connection is not
being used. The fresh water connection should be disconnected (i.e., the non-toxic drinking
hose disconnected) when the recreation vehicle is unattended for any amount of time.

The City Water connection allows you to power ll you fresh water tank. It can also be used
as a fresh water supply using your non-toxic drinking hose.
     

1. Connect the fresh water hose to the CITY WATER inlet.
2. Set the color-coded valves to the CITY WATER setting (refer to the Utility Center label
for valve conguration).
3. Connect other end of the hose to the pressurized fresh water source.
Turn ON the pressurized water source.
A check valve is located inside the city water connection inlet on the utility
center. NEVER         
. It will cause  dam-
age to the valve function and the inlet will leak water.
