Storage
Draining Fuel
> Place an approved gasoline container below the carburettor, and use a funnel to avoid
spilling fuel.
> Remove the carburettor drain bolt and sediment cup, and then move the fuel valve lever to
the ON position.
> After all the fuel has drained into the container, reinstall the drain bolt and sediment cup.
Tighten them securely.
Fuel Valve Lever
O-Ring
Sediment Cup
Drain Bolt
Washer/Gasket
Long Term Storage
Preventing Seizing
When storing machine for longer than a period of 8 weeks, the following procedure should be followed:
> Remove and Replace engine oil. Remove Spark plug and pour 15ml of fresh engine oil through the sparkplug
hole.
> Pull the starter grip several times to distribute the oil around the cylinder walls.
> Reinstall the Sparkplug. Pull the starter cord until resistance is felt. This ensures the valves are closed
preventing moisture build up.
> Return the recoil grip gently.