EasyManua.ls Logo

JDS Uniphase HST-3000 - Overview

JDS Uniphase HST-3000
24 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 24 of 24
5. Configure Test Select Configuration to configure test setting. Configure your test as
follows. Leave all other values at default, unless specified in the Work
Order.
For Layer 2 Testing:
For Layer 3 IP Testing:
6. View Results Press the Cancel Key twice, then select Results.
7. Check AutoNeg Stats For Copper (RJ-45) connections, if Auto Negotiation was enabled in the
Link Initiation Setup, press the Right Arrow key until Link Status is
displayed. Verify that Link Config ACK = Yes and Duplex = Full.
8. Test Inform the A-side technician that you are ready for test.
Menu
Option
Value
Comment
Link
Settings
Auto Neg
See Work Order
Set to same values as
Ethernet switch port.
Speed
See Work Order
Duplex
Full
RJ-45 Port Setting
Auto Sensing
Electrical option
Laser Enable
Yes
Optical option
Menu
Option
Value
Comment
Link
Settings
Auto Neg
See Work Order
Set to same values as
Ethernet switch port.
Speed
See Work Order
Duplex
Full
RJ-45 Port Setting
Auto Sensing
Electrical option
Laser Enable
Yes
Optical option
IP Settings
ARP Mode
Disable
Dest Adress See Work Order
IP Address of A side
HST-3000
Source Type
Static
Source Addr
See Work Order
Subnet Mask
See Work Order
Default Gateway
See Work Order