Page 23 of 28
Technical Support tac@jdsu.com 1 866 228-3762
Systems Engineer Dave.Baker@jdsu.com 321-243-0600
2. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
3. Setup Press the SETUP soft key on the top right side of screen.
For Electrical handoffs: Select the indicated folders and configure your
test as follows.
Select
ETHERNET 1000BASE-T SFP
Interface,
Physical Layer
Set to same value as Ethernet
switch port.
Options only displayed if Auto
Negotiate = Off
For Optical handoffs: Select the indicated folders and configure your
test as follows.
Select desired optical SFP
(1000BASE-SX, 1000BASE-LX,
etc.)
Interface,
Physical Layer
Set to same value as Ethernet
switch port.
Leave all other values at default, unless specified in the Work Order.
4. View Results Press the RESULTS button, to display the Results screen.
5. Start TrueSpeed Press the TrueSpeed Test soft key.
6. Select Config Select the Configs tab. If this is the first time using the RFC2544 test,
tap [New], enter a name for the new configuration, then tap [OK].
Otherwise, choose the saved Test Configuration.