EasyManua.ls Logo

Jenn-Air CVG 4380 User Manual

Jenn-Air CVG 4380
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
m'_'l=/"-' w-'_¢l=_ TripleBayC°nventi°nal Burner I 1
mn_ --_:_,,[e:_. Gas GrillCooktop WBmWJENN-AIR
m-./-1ill _I Illi_ _:'] ModelCVG4380 403WESTFOURTHS+REE_,O_,+_E_0.,,_0_0+
Dimensions Shown in Both Inches and Centimeters.
NOTICE TO INSTALLER: Leave these instructions with the appliance.
NOTICE TO CONSUMER: Retain these instructionsfor future reference.
BLOWERMAYBE I
ROTATEDFOR ..... /_
APPLIANCE PRESSURE
BYLOOSENING NUTS
AROUNDSLOWER
INLET.ACCESSIBLE
INSIDEVENTILATION
See cut out
(SEEDUCTrNGINSTALLA- Sugge_uons
TIONINSTRUCTIONS.) 1-4on page2.
|!
Clearance
Requlmd
GREASE
CONTAINER COVER
WIRINGCOVERBOX _ APPLIANCE PRESSURE
BAFFLE |_* REGULATOR
A
_ INSTRUCTIONSTO INSTALLER (_._
_, Dimension"A" - Provide2" rain. (5.08 cm) cabinetclearance to motorfor cooling
purpose.
NOTE: Wherepossible,6" (15.54cm) is recommendedfor motor/blowerservice.
;_ SideClearance- Grillsinstalledneara sidewallmustallowa minimumclearanceof 6"
(15.24cm) formaximumventilationperformance,but maybe safelyinstalledas near
as 2" (5.08cm) froma sidewallif requiredby spacelimitations.
_, Accessmustbe providedto removeandemptygreasecontainer. 8101P214-60
(07-98-02)
Question and Answer IconNeed help?

Do you have a question about the Jenn-Air CVG 4380 and is the answer not in the manual?

Jenn-Air CVG 4380 Specifications

General IconGeneral
BrandJenn-Air
ModelCVG 4380
CategoryCooktop
LanguageEnglish

Summary

Installation Overview and Installer Instructions

Dimensions and Clearances

Displays dimensions and required clearances for installation.

Cabinet Clearance for Cooling

Specifies minimum cabinet clearance for motor cooling purposes.

Motor/Blower Service Clearance

Recommends clearance for motor and blower service access.

Side Wall Clearance for Ventilation

Details minimum side wall clearance for optimal ventilation performance.

Grease Container Access

Mandates provision of access for grease container removal and emptying.

Cabinetry Installation Requirements

Vertical and Depth Clearances

Defines minimum vertical and maximum depth clearances for cabinets above the cooktop.

Overhead Storage Caution

Warns about risks associated with cabinet storage above surface units.

Appliance Installation Procedures

Ducting and Cutout Preparation

Outlines preparation for ducting and cutouts according to illustrations.

Code Compliance

Stresses adherence to local codes and National Fuel Gas Code standards.

Electrical Requirements

Details voltage, amperage, and grounding requirements for the electrical supply.

Grounding Instructions

Provides critical instructions for proper electrical grounding of the appliance.

Gas Supply Connection

Guides on connecting the gas supply, including shutoff valves and leak testing.

Countertop Preparation

Lists steps for preparing the countertop, including chamfering and corner radius.

Horizontal Clearance to Combustibles

Specifies minimum horizontal clearance from the appliance to combustible construction.

Air Shutter and Flame Adjustments

Surface Burner Air Shutters

Explains how to adjust air shutters on surface burners for optimal flame appearance.

Grill Burner and Surface Burner Air Shutters

Details adjustment for combined grill and surface burner air shutters.

Procedure for Low Flame Adjustment

Step-by-step guide to adjust the low flame setting for burners.

Flame Appearance Guide

Describes the characteristics of a properly adjusted flame, blue and steady.

Pressure Testing and Regulator Conversion

Gas Supply Pressure Requirements

Outlines pressure testing requirements for the appliance pressure regulator.

System Pressure Testing Precautions

Advises on precautions during gas supply piping system pressure testing.

Appliance Pressure Regulator Conversion

Maxitrol Regulator Conversion

Instructions for converting a Maxitrol appliance pressure regulator to LP gas.

Harper-Wyman Regulator Conversion

Steps to convert a Harper-Wyman regulator by inverting the cap.

Orifice Hood Conversion for LP Gas

Explains replacing natural gas orifice hoods with LP gas orifice hoods.

LP Gas Conversion Procedures

LP Gas Conversion Steps

Details the four steps required to convert the appliance from Natural Gas to LP Gas.

Control Settings Guide

Cooktop Control Settings Guide

Provides guidance on using HI, Med, and Lo flame settings for various cooking needs.

Minimum Spacing Requirements

Triple Bay Cooktop Spacing

Shows minimum spacing when combining a Triple Bay cooktop with another unit.

Double Bay Cooktop Spacing

Illustrates minimum spacing for a Double Bay cooktop with a Triple Bay unit.

Single Bay Cooktop Spacing

Depicts minimum spacing for a Single Bay cooktop with a Triple Bay unit.

Downdraft Cooktop Spacing

Shows spacing requirements when combining with any Downdraft Cooktop model.

Propane Gas (LP) Conversion Instructions

Conversion Warning

Emphasizes that conversion must be done by authorized personnel due to safety risks.

Power and Gas Off Warning

Stresses turning off electrical power and gas before commencing conversion.

Model CVG 4380 Series Gas Pressure

Lists required manifold and incoming gas pressures for propane conversion.

Propane Gas Orifice Hoods

Identifies supplied orifice hoods for propane conversion and their part number.

Propane Gas Input Specifications

Details the BTU/hr input and orifice sizes for each burner during propane conversion.

Natural Gas Conversion Instructions

Conversion Warning

Reiterates that Natural Gas conversion must be performed by authorized personnel.

Power and Gas Off Warning

Instructs to turn off power and gas before starting the conversion back to Natural Gas.

Model CVG 4380 Series Gas Pressure

Specifies manifold and incoming gas pressures required for Natural Gas conversion.

Orifice Hood Replacement for Natural Gas

Directs to replace orifice hoods with original Natural Gas ones for conversion back.

Pressure Regulator and Flame Adjustment

Guides on inverting the pressure regulator cap and adjusting low flame settings.

Natural Gas Input Specifications

Lists BTU/hr input and orifice sizes for each burner when using Natural Gas.

Required Adjustments at Time of Installation

Compliance with Codes

Emphasizes conforming to local codes and National Fuel Gas Code for installation.

Natural Gas vs. LP Gas Fuel

Notes the default fuel is Natural Gas and directs to LP conversion instructions if needed.

Gas Leak Testing

Mandates testing all external gas connections for leaks without using an open flame.

Electrical Connection Testing

Requires testing all electrical connections for proper function.

Air Shutter and Valve Adjustment

Instructs to adjust air shutters for proper flame and valves for low flame settings.

Ventilation System Testing

Requires testing the ventilation system for correct installation and performance.

Troubleshooting Downdraft System

Suggests checking ducting installation for downdraft system issues.

Contacting Installer/Service

Advises contacting the installer or service contractor for persistent ventilation problems.

Ducting Instructions and Requirements

Ducting Requirements

Specifies that ducting must conform to local codes and 300 CFM minimum requirements.

Ducting Planning

Advises planning the duct run and using the Duct Length Chart for equivalent length.

Blower Range Setting

Explains when to shift the blower from 'Low Range' to 'High Range' based on duct length.

General Ducting Considerations

Provides general guidelines for duct material, transitions, and bends.

High Altitude Installations

Advises reducing allowable duct run by 20% for high altitude installations.

Canadian Installation Codes

Notes compliance with Canadian codes for installation in Canada.

Duct Length Chart and Calculation

System Sketch and Calculation

Guides on sketching the duct system and entering the run into the Duct Length Chart.

Duct Fitting Equivalent Lengths

Lists equivalent straight duct length for various duct fittings used in calculations.

Example Duct Length Calculations

Provides examples of calculating total equivalent duct length for different duct runs.

Install the Duct Hardware

Instructs on installing duct hardware using quality materials per instructions.

Duct Fitting Equivalent Lengths Details

6-Inch Duct Fittings

Details equivalent lengths for 6-inch duct elbows, transitions, and caps.

3-1/4" x 10" Duct Fittings

Lists equivalent lengths for 3-1/4" x 10" duct elbows, transitions, and caps.

Specialty Duct Fittings

Covers equivalent lengths for roof jacks and thermal breaks.

Straight Duct Lengths

Provides equivalent lengths for straight 6-inch and 3-1/4" x 10" duct sections.

Blower Range Shifting Procedure

Blower Range Adjustment Criteria

Explains criteria for shifting the blower to 'High Range' based on duct length exceeding 30 feet.

Procedure for Shifting Blower

Step-by-step guide to shift the blower to 'High Range' by removing the restrictor ring.

Optional Duct Arrangement Under Concrete Slab

Ducting Configurations

Illustrates various duct arrangements under concrete slabs for different scenarios.

Do and Don't for Ducting

Provides guidelines on proper and improper ducting practices to avoid restrictions.

Wall Caps and Thermal Breaks

Details specific wall caps and thermal breaks, their part numbers, and impact on duct length calculation.

Related product manuals