EasyManua.ls Logo

Jet FA Series - How to Set up the Wiring; How to Connect the Voltage

Jet FA Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
HOW TO SET UP THE WIRING (3-PHASE 220/440V MODEL)
Remove the motor side cover (No. 364). to expose the connector panel with female sockets L1, L2, L3, L4, H1, H2, H3 and H4, and
male plugs 1, 2, 3 and 4. (Fig.3)
Engage them as specified below, corresponding to the voltage of power supply. (Fig. 4 & 5)
Figure 3 Figure 4 Figure 5
How to connect the Voltage
220V Male 1-Female L1, Male 2-Female L2, Male 3-Female L3, and Male 4-Female L4
440V Male 1-Female H1, Male 2-Female H2, Male 3-Female H3, and Male 4-Female H4
Install the motor side cover (No. 364) again, with care to ensure the wires are not caught and pressed between the cover and the
hoist body.
HOW TO SET UP THE WIRING (1-PHASE 115/230V MODEL)
Remove the motor side cover (No. 364). to expose the connector panel with 2 female sockets (one marked 115V, and another
marked 230V) as well as one male plug If the voltage of the power source is 115V, engage the male plug to the female socket
marked 115V, and if the voltage is 230V, engage the male plug to the female socket 230V.
NOTE: Once the power source is disconnected, you must wait 3 minutes before converting to a new voltage power source.
This allows the capacitors to discharge, and protects the pins in the housings from sparking.
After the power supply wiring has been correctly connected, install the motor side cover (No. 364) again, taking care to ensure the
wires are not caught and pressed between the cover and the hoist body.
NOTE: when engaging the plug into the socket, be sure that they are fully engaged when they are connected and that the
tab is locked together with the socket. Press down the tab on the male plug when you want to disengage them.

Related product manuals