Reduce load to motor; do not press so
hard.
Check power line for proper voltage.
Frequent fuse or circuit
breaker failure.
Reduce load to motor; do not press so
hard.
Electrical circuit overload; too many
electrical machines running on same
circuit.
Turn off other machines and try again.
Incorrect fuse or circuit breaker
Have electrician upgrade service to outlet.
Wheel(s) out of balance; wobbling or
not rotating concentric to arbor.
Dress wheel or replace it. Adjust wobble
by rotating flange as needed.
Secure machine firmly to bench or stand.
10.2 Digital readout error codes
Table 4
Internal electronic overload has been tripped.
Do not overload motor; reduce pressure of
workpiece against wheels.
IGBT protection activated.
Inspect wire connections to U/V/W for possible
short circuits. Verify that motor rating
corresponds to AC motor drive output power.
Excessive input voltage (exceeds AC driver
limits).
Low voltage; AC motor driver detects that DC
bus voltage has fallen below minimum
threshold
Make sure input voltage falls within range of AC
motor input voltage range. Check for abnormal
load in motor.
Low input voltage (below AC driver limits)
* WARNING: Some corrections may required a qualified electrician.