3.12. Ensure flue is of sufficient length (see Fig. 10). Extra flue is available.
3.13. After installation paint exposed steel flue, cowl, etc above the roof line
with good quality external enamel to protect against corrosion. This will
require repainting from time to time.
3.14. With rotating Superjet Hex model, fireplace unit and flue rotate through
180E. Ensure that electrical connection is spiral flexible conduit.
3.15. Ensure rotating cowl turns freely and safety screw is engaged.
NOTE: THATCH OR TIMBER ROOFS
(a ) Where one of the above models is used in a thatch or timber-roofed
home, the space between the steel flue and the thatch should be
very well packed with the fibreglass insulation material. Please
ensure that the steel flue is thoroughly insulated. A galvanised
sleeve through the thatch should be provided for as shown in Fig. 6.
(b) It is advisable to have the top of the steel flue above the apex of the
roof. Do not fit fixed steel chimney cowl. If wind downdraught is
apparent, fit Jetmaster rotating cowl.