INSTALLATION AND OPERATOR'S
MANUAL
Model number: JSI-xxxxTL series for Australia Rev. 1.4

Questions and Answers

  • C
    Christine WhiteJul 31, 2025
    What to do if JFY tech Inverter displays E03 Grid fault?
    • B
      brendaherreraJul 31, 2025
      If your JFY tech Inverter shows an E03 Grid fault, ensure that the grid voltage and frequency are within the specified limits. This will help resolve the issue.
  • F
    fjeffersonAug 5, 2025
    What to do if JFY tech JSI-1500TL displays E01 Isolation error?
    • J
      jessica57Aug 5, 2025
      If you're seeing an E01 Isolation error on your JFY tech Inverter, check the impedance between PV (+) and PV (-) and ensure the inverter is properly earthed. The impedance should be greater than 2MΩ.
  • B
    Brent RodriguezAug 9, 2025
    Why JFY tech JSI-1500TL Inverter displays W02 Vin overvoltage?
    • S
      Susan YoungAug 9, 2025
      If your JFY tech Inverter is showing a W02 Vin overvoltage error, check the open-circuit voltage (Voc) of the PV string. Ensure it's not exceeding or too close to the maximum input DC voltage specified for your inverter model.
  • M
    monica89Aug 14, 2025
    What to do if JFY tech Inverter displays E02 Ileak error?
    • C
      Christine StoneAug 15, 2025
      If your JFY tech Inverter displays an E02 Ileak error, it means the leakage current is too high. Disconnect the PV string inputs and inspect the AC system connected to your JFY tech Inverter.
  • J
    Julie WagnerAug 20, 2025
    How to troubleshoot W01 No grid error on JFY tech JSI-1500TL Inverter?
    • J
      Jennifer DuarteAug 20, 2025
      If your JFY tech Inverter displays a W01 No grid error, check the grid connection cables to ensure they are properly connected.
  • K
    kevinbellAug 25, 2025
    What to do if JFY tech Inverter has no display in LCD or LED?
    • B
      Bradley BoydAug 25, 2025
      If there is no display on the LCD or LED of your JFY tech Inverter, check the PV-input connections to ensure they are properly connected.

JFY tech JSI-1500TL Specifications

General IconGeneral
ModelJSI-1500TL
Max. DC Power1800W
Nominal DC Voltage360V
Number of MPPT1
Max. Input Current10A
Max. Short Circuit Current12A
Nominal AC Power1500W
Nominal AC Voltage230V
Power Factor>0.99
THDi<3%
Euro Efficiency96.5%
DC ConnectionMC4
Protection DegreeIP65
TopologyTransformerless
CoolingNatural Convection
Nominal Grid Frequency50/60Hz
AC Frequency Range47Hz-52Hz/57Hz-62Hz
Operating Temperature Range-25°C to +60°C
Relative Humidity0-100%