EasyManua.ls Logo

JFY tech JSI-5000TL - User Manual

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
www.JFY-tech.com
Solar Inverters
INSTALLATION AND OPERATOR'S
MANUAL
Model number: JSI-xxxxTL series for Australia Rev. 1.4

Questions and Answers

  • K
    Kimberly WebsterAug 6, 2025
    What to do if JFY tech JSI-5000TL displays E03 Grid fault?
    • D
      Douglas FisherAug 6, 2025
      If your JFY tech Inverter shows an E03 Grid fault, ensure that the grid voltage and frequency are within the specified limits. This will help resolve the issue.
  • A
    Ashley CaseyAug 11, 2025
    What to do if JFY tech JSI-5000TL Inverter displays E01 Isolation error?
    • R
      Reginald WilsonAug 11, 2025
      If you're seeing an E01 Isolation error on your JFY tech Inverter, check the impedance between PV (+) and PV (-) and ensure the inverter is properly earthed. The impedance should be greater than 2MΩ.
  • R
    Rebecca BrandtAug 16, 2025
    Why JFY tech JSI-5000TL displays W02 Vin overvoltage?
    • K
      krileyAug 16, 2025
      If your JFY tech Inverter is showing a W02 Vin overvoltage error, check the open-circuit voltage (Voc) of the PV string. Ensure it's not exceeding or too close to the maximum input DC voltage specified for your inverter model.
  • J
    jackson49Aug 21, 2025
    What to do if JFY tech JSI-5000TL Inverter displays E02 Ileak error?
    • M
      Melissa WilliamsAug 21, 2025
      If your JFY tech Inverter displays an E02 Ileak error, it means the leakage current is too high. Disconnect the PV string inputs and inspect the AC system connected to your JFY tech Inverter.
  • G
    gfordAug 27, 2025
    How to troubleshoot W01 No grid error on JFY tech JSI-5000TL Inverter?
    • H
      Hayley MurphyAug 27, 2025
      If your JFY tech Inverter displays a W01 No grid error, check the grid connection cables to ensure they are properly connected.
  • C
    Cynthia RogersAug 31, 2025
    What to do if JFY tech JSI-5000TL Inverter has no display in LCD or LED?
    • D
      Dylan WilliamsAug 31, 2025
      If there is no display on the LCD or LED of your JFY tech Inverter, check the PV-input connections to ensure they are properly connected.

JFY tech JSI-5000TL Specifications

General IconGeneral
Number of MPP trackers2
Rated AC Power5000 W
Max. AC Power5000 VA
Max. Output Current22.8 A
Rated AC Voltage230 V
AC Voltage Range180-280 V
Rated Frequency50/60 Hz
Power Factor>0.99
THDi<3%
DC ConnectionMC4
Protection DegreeIP65
Operating Temperature Range-25°C to +60°C
Max. Input Current11A
Max. Efficiency97.0%
Euro Efficiency97%
AC ConnectionScrew Terminals
CoolingNatural