Questions and Answers

  • D
    Daniel ThompsonAug 6, 2025
    What to do if JFY tech Inverter displays E03 Grid fault?
    • H
      Heidi WilliamsAug 6, 2025
      If your JFY tech Inverter shows an E03 Grid fault, ensure that the grid voltage and frequency are within the specified limits. This will help resolve the issue.
  • K
    Kelly MartinezAug 11, 2025
    What to do if JFY tech JSI-3000TL displays E01 Isolation error?
    • B
      Brandon ReedAug 11, 2025
      If you're seeing an E01 Isolation error on your JFY tech Inverter, check the impedance between PV (+) and PV (-) and ensure the inverter is properly earthed. The impedance should be greater than 2MΩ.
  • B
    bonealAug 16, 2025
    Why JFY tech Inverter displays W02 Vin overvoltage?
    • J
      Jennifer GonzalesAug 16, 2025
      If your JFY tech Inverter is showing a W02 Vin overvoltage error, check the open-circuit voltage (Voc) of the PV string. Ensure it's not exceeding or too close to the maximum input DC voltage specified for your inverter model.
  • M
    Matthew GarciaAug 20, 2025
    What to do if JFY tech JSI-3000TL Inverter displays E02 Ileak error?
    • K
      Kayla BrownAug 20, 2025
      If your JFY tech Inverter displays an E02 Ileak error, it means the leakage current is too high. Disconnect the PV string inputs and inspect the AC system connected to your JFY tech Inverter.
  • S
    Sara SimmonsAug 26, 2025
    How to troubleshoot W01 No grid error on JFY tech JSI-3000TL Inverter?
    • J
      Jamie BirdAug 27, 2025
      If your JFY tech Inverter displays a W01 No grid error, check the grid connection cables to ensure they are properly connected.
  • B
    Bridget WalkerAug 31, 2025
    What to do if JFY tech JSI-3000TL Inverter has no display in LCD or LED?
    • R
      rmatthewsAug 31, 2025
      If there is no display on the LCD or LED of your JFY tech Inverter, check the PV-input connections to ensure they are properly connected.

JFY tech JSI-3000TL Specifications

General IconGeneral
ModelJSI-3000TL
Max. DC Voltage550 V
Nominal AC Voltage230 V
Rated AC Output Voltage230 V
Maximum Efficiency97.5%
Cooling MethodNatural Convection
Protection LevelIP65
Nominal AC Power3 kW
Rated AC Output Power3 kW
Max. AC Power3.3 kVA
Maximum AC Output Power3.3 kVA
AC Output Frequency50Hz/60Hz
Operating Temperature Range-25°C to 60°C