EasyManua.ls Logo

Jntech JNP1K5L-V5 - User Manual

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manaul
Solar Pumping Inverter
JNP550L-V5
JNP750L-V5
JNP1K1L-V5
JNP1K5L-V5
JNP2K2L-SE-V5
JNP2K2L-SE-V5-EN-V1.0

Table of Contents

Other manuals for Jntech JNP1K5L-V5

Questions and Answers

  • B
    Barbara CarrilloSep 10, 2025
    What does it mean when my Jntech JNP1K5L-V5 Inverter shows 'Temperature sensor fault'?
    • K
      Kevin MorganSep 10, 2025
      If your Jntech Inverter indicates a 'Temperature sensor fault', it means the sensor is either not properly connected or is damaged. If this issue occurs frequently, contact your supplier.
  • K
    Kristy RayAug 22, 2025
    Why does my Jntech JNP1K5L-V5 show 'Array over-voltage'?
    • D
      Douglas RichmondAug 23, 2025
      If the Jntech Inverter displays 'Array over-voltage,' it signifies that the DC input voltage exceeds the inverter's maximum input voltage. To resolve this, check the maximum output voltage of the array and ensure it remains below the inverter's maximum input voltage.
  • K
    Kimberly PhillipsAug 25, 2025
    What causes 'Inverter AC output over current' on a Jntech JNP1K5L-V5?
    • Y
      youngnicholeAug 25, 2025
      If your Jntech Inverter reports 'Inverter AC output over current', it could be due to several reasons: the pump motor's power capacity exceeds the rated output, the pump motor is locked or damaged, or the pipe system design is unreasonable. Inspect the pump motor to ensure it is working correctly and check if the pipeline system matches the water pump specifications. If this issue occurs frequently, contact your supplier.
  • R
    richard62Aug 26, 2025
    What should I do if my Jntech Inverter displays 'Grid power overvoltage'?
    • M
      Michelle CunninghamAug 26, 2025
      If your Jntech Inverter shows 'Grid power overvoltage', it means that the local grid power voltage is unstable and high, or there is a hardware failure. Check the input of the AC power, and if the voltage value is too high, disconnect the grid power. Contact your supplier for further assistance.
  • J
    Jeremy MooreAug 27, 2025
    What to do if my Jntech JNP1K5L-V5 Inverter has a 'Short circuit fault (Nonrecoverable)'?
    • M
      mforbesAug 28, 2025
      If your Jntech Inverter displays a 'Short circuit fault (Nonrecoverable)', it indicates a short circuit in the output wires. Check the output wires for any short circuits. If the issue persists, contact your supplier.
  • T
    Thomas MartinezAug 29, 2025
    Why is my Jntech JNP1K5L-V5 showing 'Grid power undervoltage'?
    • G
      ggordonAug 29, 2025
      If your Jntech Inverter shows 'Grid power undervoltage', it could be because the grid power switch isn't closed or the grid input is unstable and lower than the minimum operating voltage. First, check if the AC input switch is closed. Then, verify that the local grid voltage is normal.
  • D
    dwayneruizSep 18, 2025
    How to fix State 109 Dry alarm on Jntech JNP1K5L-V5?
    • P
      Patricia ColemanSep 18, 2025
      If your Jntech Inverter shows a State 109 Dry alarm, it indicates that the water level of the water source is lower than the lower level sensor, possibly even lower than the pump inlet. First, check the water level. If the water level is adequate, check for air inside the pump. Also, verify the position of the water level sensor.
  • D
    David ClarkSep 12, 2025
    What to do if my Jntech JNP1K5L-V5 shows Fault100 Driver over-current?
    • T
      Tonya VillarrealSep 12, 2025
      If your Jntech Inverter displays a Fault100 Driver over-current error, the possible cause may be a short circuit of the inverter output wires or hardware circuit damage. Check for any short circuits between the 3-phase output wires.
  • J
    Joseph ArnoldSep 8, 2025
    What should I do if my Jntech JNP1K5L-V5 Inverter displays an 'Overflow alarm'?
    • D
      Dawn NguyenSep 8, 2025
      If your Jntech Inverter displays 'Overflow alarm' it means that the water level in the container is higher than the high-end level sensor. If this occurs repeatedly, inspect the site and adjust the water level sensor to a suitable height.
  • G
    Gregory GraySep 5, 2025
    What to do when my Jntech JNP1K5L-V5 reports 'Output phase lose'?
    • H
      hwashingtonSep 5, 2025
      If your Jntech Inverter displays 'Output phase lose', it indicates a phase loss in the inverter output. Check if the output wires are properly connected and fixed. If this issue persists, contact the supplier.

Summary

Preface

Manual Instruction

Describes the manual's content and scope for JNP inverters.

1 Safety Instructions

Warning!

Safety warning emphasizing professional installation and training for JNPxL inverters.

4 Installation Procedure

4.2 Installation Steps

Outlines the sequential steps for performing the inverter installation.

5 Installation

5.1 Installation Site Required

Specifies environmental and location requirements for safe inverter installation.

5.3 Installation of Inverter

Details the physical mounting procedures for the inverter.

6 Electrical Connection

6.1 Connecting Terminals of Inverter

Describes the function and connection of various terminals on the inverter.

6.4 AC Side Electrical Connection

Details the procedures for connecting the AC power input and output.

6.5 DC Side Connection

Details the procedures for connecting the DC power input from PV arrays.

7 Commissioning

7.2 Inverter Commissioning

Details the procedures for commissioning the solar pumping inverter.

8 LCD Panel Operating Instructions

8.3 System parameter inquiry and setting

Guides on how to query system parameters and perform settings.

8.4 Malfunction Description

Explains how to identify and interpret malfunctions and fault codes.

9 Malfunction and Troubleshooting

9.1 Troubleshooting

Provides detailed troubleshooting steps for common inverter malfunctions.

10 Appendix A

Jntech JNP1K5L-V5 Specifications

General IconGeneral
BrandJntech
ModelJNP1K5L-V5
CategoryInverter
LanguageEnglish

Related product manuals