Questions and Answers

  • C
    Christopher BellAug 11, 2025
    What to do if my Jntech JNP550L-V5 Inverter shows Fault100 Driver over-current?
    • M
      Mary GriffinAug 11, 2025
      If your Jntech Inverter displays a Fault100 Driver over-current error, the possible cause may be a short circuit of the inverter output wires or hardware circuit damage. Check for any short circuits between the 3-phase output wires.
  • P
    Pamela YoungAug 16, 2025
    What to do if my Jntech JNP550L-V5 shows State 101 PV Array under-voltage?
    • J
      Jonathan ChavezAug 16, 2025
      If your Jntech Inverter shows a State 101 PV Array under-voltage error, it means that the output energy from the PV array is not enough. Check the PV input voltage and ensure it is within the inverter's input voltage range. This is normal on cloudy days, in the morning, and late in the afternoon.
  • G
    Glenn SmithAug 22, 2025
    What to do if my Jntech JNP550L-V5 displays State 114 Overflow alarm?
    • N
      Nancy SantosAug 22, 2025
      If the Jntech Inverter displays a State 114 Overflow alarm more than once, it means the water level in the tank is higher than the set higher level alarm. Check the site and set the water level sensor at a proper height.
  • M
    Mario BradleyAug 29, 2025
    Why does my Jntech Inverter show State 110 Weak sunshine?
    • P
      pamela45Aug 29, 2025
      The State 110 Weak sunshine message on your Jntech Inverter indicates that the energy produced by the PV array is low. This usually appears in the early morning, late in the afternoon, and on cloudy days. This function protects the motor of the pump.
  • L
    Leslie ClaySep 4, 2025
    How to fix State 109 Dry alarm on Jntech Inverter?
    • R
      Rebekah RossSep 4, 2025
      If your Jntech Inverter shows a State 109 Dry alarm, it indicates that the water level of the water source is lower than the lower level sensor, possibly even lower than the pump inlet. First, check the water level. If the water level is adequate, check for air inside the pump. Also, verify the position of the water level sensor.

Jntech JNP550L-V5 Specifications

General IconGeneral
ModelJNP550L-V5
CategoryInverter
Rated Power550W
Output Voltage220V AC
Output WaveformPure Sine Wave
CoolingFan Cooling
Weight4.5kg
Output Frequency50Hz/60Hz
Protection FeaturesOverload, Short Circuit, Over Voltage, Over Temperature
Operating Temperature-10°C to 50°C

Related product manuals