Dripping
Mist valve is excessively open
for existing conditions.
Dirt in the reservoir.
Use the mist valve to
reduce the mist.
Perform the cleaning
procedures.
Troubleshooting
PROBLEM
Fan does not
turn on
PROBABLE CAUSE
The On/Off button is not
in ON position.
Not plugged to the
electrical outlet.
No electrical power on
the outlet.
SOLUTION
Turn the button to ON
position.
Make sure fan is plugged
into live electrical outlet.
Press reset button on GFCI
plug.
Not Misting
No water in the water
reservoir.
The mist adjustment valve
is closed.
Defective/Dirty water pump
Add water to the reservoir.
Open the mist valve.
Clean the water pump.
7