21
LP69910 (12/07/2020) 3 CU FT GATOR FERTILIZER SPREADER
Troubleshooting
SPN Error Description Troubleshooting Guide
6208
MD2 High VBAT
Fault
Motor Driver 2
voltage above 18V
The module will stop operating the spreader if the system voltage
rises above 18V. This is a latching fault to protect the electronics.
The module must be power cycled to recover from a high voltage
fault. Note that the Control Module high voltage fault is not the
same as the Display Module high voltage fault.
6209
MD2 High VBAT
Warning
Motor Driver 2
voltage above 16V
No action is necessary. The module will continue operating the
spreader with a system voltage between 16V and 18V but will stop
operating the spreader if the system voltage rises above 18V. Note
that the Control Module high voltage warning is not the same as the
Display Module high voltage warning.
6210
MD2 Low VBAT
Fault
Motor Driver 2
voltage below 8V
The module will stop operating the spreader if the system voltage
falls below 8V. This is a latching fault to protect the electronics. The
module must be power cycled to recover from a low voltage fault.
Note that the Control Module low voltage fault is not the same as
the Display Module low voltage fault.
6211
MD2 Low VBAT
Warning
Motor Driver 2
voltage below 9V
No action is necessary. The module will continue operating the
spreader with a system voltage between 8V and 9V but will stop
operating the spreader if the system voltage falls below 8V. Note
that the Control Module low voltage warning is not the same as the
Display Module low voltage warning.
6212
MD2 No
Communication
Motor Driver 2 is
not responding at
power up
The module will not operate if it cannot communicate with the
internal motor driver at power up. Power cycle the module. If the
error is still active contact Superior Tech for support.
6213
MD2 Lost
Communication
Motor Driver 2 has
lost communication
for 10 seconds
The module will stop operating if it loses communication with the
internal motor driver for more than 10 seconds. Power cycle the
module. If the error is still active contact Superior Tech for support.
6400
Motor Driver
Mismatch Version
Motor Driver 1 and
Motor Driver 2 have
different software
versions
The module will not operate if the software loaded in the motor
drivers does not match. Power cycle the module. If the error is still
active contact Superior Tech for support.
6401
Spreader
Type Memory
Corruption
Spreader Type
stored in memory is
not valid
The module will not operate if the software does not load the proper
spreader type from internal memory. Power cycle the module. If the
error is still active contact Superior Tech for support.