Johnson Controls Ducted Systems 1010352-UUM-N-0121
USER’S INFORMATION
MANUAL
MODELS:
All Residential Multi-position Gas Furnaces
(33 in. Models)
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Specific safety rules and precautions . . . . . . . . . . . . . . . . . . . . . . . 1
EXAMINING THE FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . 2
START-UP AND SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
How your gas furnace works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Turning off the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FURNACE MAINTENANCE - USER INFORMATION . . . . . . . . . . . . 4
External air filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cleaning your filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Blower care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Motor lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Furnace control diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Furnace maintenance - dealer/contractor . . . . . . . . . . . . . . . . . . . 5
Replacement parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Contact information
Go to website at www.york.com, then click on Contact Us and
follow the instructions.
Contact us by mail:
Johnson Controls Ducted Systems
Consumer Relations
5005 York Drive
Norman, OK 73069
Read all sections of this manual and keep the manual for
future reference.
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Specific safety rules and precautions
1. The furnace area must be kept clear and free of combustible mate-
rials, gasoline, and other flammable vapors and liquids.
2. Insulating materials may be combustible. The furnace must be kept
free and clear of insulating materials. The furnace area must be
examined when installed in an attic or other insulated space, or
when insulation is added, to be sure that the insulation material has
been kept away from the furnace.
The following warning applies to horizontally vented furnaces only.
3. The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace, air
openings to the area where the furnace is installed, or spaces
around the furnace.
4. Follow the instructions exactly as shown on the Operating instruc-
tion label on the furnace or the Start-up and shut-down instructions
of this manual when lighting the furnace or turning the furnace off.
WARNING
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
WARNING
FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone (includ-
ing cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
!
!
WARNING
FIRE OR EXPLOSION HAZARD
This furnace is designed and approved for use with Natural Gas and
(LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL OR
SOLID FUEL IN THIS FURNACE.
Burning any unapproved fuel will result in damage to the furnace heat
exchanger, which could result in Fire, Personal Injury, and/or Property
Damage.
WARNING
CARBON-MONOXIDE POISONING HAZARD
Failure to follow instructions could result in severe personal injury or
death due to carbon-monoxide poisoning, if combustion products infil-
trate into the building.
Check that all openings in the outside wall around the vent (and air
intake) pipe(s) are sealed to prevent infiltration of combustion prod-
ucts into the building.
Check that furnace vent (and air intake) terminal(s) are not obstructed
in any way during all seasons.
!
!
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls RGF1L P Series and is the answer not in the manual?

Johnson Controls RGF1L P Series Specifications

General IconGeneral
Frequency60 Hz
Fuel TypeGas
Maximum CurrentVaries with model, refer to unit nameplate
Power ConsumptionVaries with model, refer to unit nameplate
DimensionsVaries with model, refer to product data sheet
WeightVaries with model, refer to product data sheet

Summary

Furnace Safety Precautions

Specific safety rules and precautions

General safety rules and precautions for furnace use.

Furnace Installation Examination

Examination steps

Owner's responsibility for annual inspection and pre-heating season checks.

Furnace Start-Up and Shutdown Procedures

How your gas furnace works

Explanation of the furnace's heating cycle and operation.

Furnace Start-Up and Shutdown Procedures

Operating instructions

Step-by-step guide for starting and operating the furnace.

Turning off the appliance

Instructions for safely shutting down the furnace.

User Furnace Maintenance: External Air Filters

External air filters

Guidance on external air filters for furnace maintenance.

User Furnace Maintenance: Filters, Blower, and Motor

Cleaning your filter

Procedures for cleaning furnace filters.

Blower care

Instructions for blower assembly maintenance by a qualified agency.

Motor lubrication

Information on motor lubrication for the furnace.

Furnace Service and Troubleshooting

Troubleshooting problems

Steps for diagnosing and resolving furnace operational issues.

Furnace control diagnostics

Explanation of the furnace's self-diagnostic LED fault codes.

Furnace maintenance - dealer;contractor

Recommended annual maintenance tasks for dealers/contractors.

Replacement parts list

Information on obtaining replacement parts for the furnace.

Wiring diagram

Location of the unit's wiring diagram.

Residential Furnace Limited Warranty

WARRANTY TERMS

General warranty terms and conditions for residential furnaces.

ADDITIONAL CONDITIONS FOR HEAT EXCHANGER WARRANTY

Specific conditions for heat exchanger warranty coverage.

CONDITIONAL UNIT REPLACEMENT WARRANTY

Details on the conditional unit replacement option for specific models.

WARRANTY PERIOD

Chart detailing warranty periods for different furnace parts.

Warranty Service and Repair Process

FOR WARRANTY SERVICE OR REPAIR

Instructions on how to obtain warranty service or repair.

Product Registration Guide

FOR PRODUCT REGISTRATION

Guidance on registering the product for warranty purposes.

Preventive Maintenance Recommendations

MAINTENANCE

Recommendations for regular preventive maintenance.

Warranty Exclusions and Limitations

EXCLUSIONS

List of conditions and situations not covered by the warranty.