Johnson Controls Unitary Products 1083163-UIM-J-0918
SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MODELS: TM9E Series
(95% AFUE Multi-position)
INSTALLATION MANUAL
LIST OF SECTIONS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
CONDENSATE PIPING AND FURNACE
VENTING CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
COMBUSTION AIR and VENT SYSTEM . . . . . . . . . . . . . . . . . . . .19
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . .27
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . . . . .33
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
LIST OF FIGURES
Duct Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Furnace and Coil Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Combustible Floor Base Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Horizontal Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Suspended Furnace / Crawl Space Installation . . . . . . . . . . . 7
Downflow Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Side Return Cutout Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Left Side Supply Gas Pipe Arrangement . . . . . . . . . . . . . . . . . . . . . . 9
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Thermostat Chart - 1H/1C - Single Stage Furnace
(STD-ECM) - Single Stage Air Conditioner . . . . . . . . . . . . . . . . . . . 12
Thermostat Chart - 1H/2C - Single Stage Furnace
(STD-ECM) - Single Stage Air Conditioner . . . . . . . . . . . . . . . . . . . 12
Typical. Condensate drain, vertical installation . . . . . . . . . . . . . . . . 13
Upflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Downflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Horizontal Left Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Horizontal Right Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . .23
Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . .23
Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . . . . .23
Double Horizontal Combustion Air Intake and Vent Termination . . .24
Double Vertical Combustion Air Intake and Vent Termination . . . . .24
Downward Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Direct Vent Air Intake Connection and Vent Connection . . . . . . . . .24
Combustion Airflow Path Through The Furnace Casing . . . . . . . . .25
Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Attic and Crawl Space Combustion Air Termination . . . . . . . . . . . . .27
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
LIST OF TABLES
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Recommended Filter Sizes (High Velocity 600 FPM) . . . . . . . . . . . . 8
Nominal Manifold Pressure - High Fire . . . . . . . . . . . . . . . . . . . . . . 10
Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . 20
High Altitude Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Combustion Air Intake and Vent Connection
Size at Furnace (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . . . .25
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . . . . .29
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Blower Performance CFM - Any Position (without filter) . . . . . . . . . .32
These high efficiency, compact units employ induced combustion, reli-
able hot surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in upflow or
horizontal applications and may be converted for downflow applica-
tions.
These furnaces are designed for residential installation in a basement,
closet, alcove, attic, recreation room or garage and are also ideal for
commercial applications. All units are factory assembled, wired and
tested to assure safe dependable and economical installation and oper-
ation.
These units are Category IV listed and may not be common vented with
another gas appliance as allowed by the National Fuel Gas Code.
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls TM9E Series and is the answer not in the manual?

Johnson Controls TM9E Series Specifications

General IconGeneral
BrandJohnson Controls
ModelTM9E Series
CategoryFurnace
LanguageEnglish

Summary

SECTION I: SAFETY

SPECIFIC SAFETY RULES AND PRECAUTIONS

Rules for safe installation and operation of gas furnaces.

FIRE OR EXPLOSION HAZARD WARNING

Critical warnings regarding fire and explosion risks during installation and operation.

SAFETY REQUIREMENTS AND CAUTIONS

General safety requirements and cautions for installation compliance and precautions.

COMBUSTION AIR QUALITY

Lists contaminants that can affect furnace operation and require outdoor air.

CODES AND STANDARDS

Lists national and local codes applicable to furnace installation.

MASSACHUSETTS INSTALLATION SAFETY

Specific safety requirements for furnaces installed in Massachusetts.

FURNACE LOCATION AND CLEARANCES

INSTALLATION IN FREEZING TEMPERATURES

Guidelines for installing the furnace in areas susceptible to freezing.

RESIDENTIAL GARAGE INSTALLATION

Specific requirements for installing the furnace in a residential garage.

CLEARANCES FOR ACCESS;SERVICE

Recommended clearances for accessing and servicing the furnace unit.

SECTION II: DUCTWORK

DUCTWORK GENERAL INFORMATION

General principles and requirements for designing and installing duct systems.

DUCT SYSTEM SIZING WARNING

Warning about the critical importance of proper duct system sizing for furnace operation.

UPFLOW;HORIZONTAL DUCTWORK CONNECTION

Procedures for connecting ductwork in upflow and horizontal furnace configurations.

DOWNFLOW DUCTWORK INSTALLATION

Guidelines for installing ductwork in the downflow furnace configuration.

COIL INSTALLATION

Instructions for installing the indoor coil with the furnace.

RETURN PLENUM INSTALLATION

Details on connecting return air plenums for various configurations.

HORIZONTAL APPLICATION

Guidance for installing the furnace in a horizontal position.

ATTIC INSTALLATION

Specific considerations for installing the furnace in an attic space.

SUSPENDED FURNACE; CRAWL SPACE INSTALLATION

Instructions for suspending the furnace in crawl spaces or from joists.

SECTION III: FILTERS

FILTER INSTALLATION

Instructions and precautions for installing furnace filters.

SIDE RETURN FILTER CONSIDERATIONS

Specific considerations for filter installation in side return configurations.

HORIZONTAL AND DOWNFLOW FILTERING

Guidelines for filter placement in horizontal and downflow ductwork.

SECTION IV: GAS PIPING

GAS SAFETY

Critical safety information regarding gas piping installation and pressure.

GAS PIPING INSTALLATION GUIDELINES

Instructions for proper gas piping connections and materials.

LP GAS AND HIGH ALTITUDE CONVERSIONS

Procedures for converting the furnace for LP gas and high altitude operation.

SECTION V: ELECTRICAL POWER

ELECTRICAL POWER CONNECTIONS

Guidelines for making safe and correct electrical power connections.

SUPPLY VOLTAGE CONNECTIONS

Detailed instructions for connecting the main power supply to the furnace.

LOW VOLTAGE CONTROL WIRING

How to connect low voltage wiring for thermostat and accessories.

SECTION VI: CONDENSATE PIPING AND FURNACE VENTING CONFIGURATION

ACCESSORY CONNECTIONS

Connecting electronic air cleaners, humidifiers, and twinning furnaces.

CONDENSATE DRAIN LOCATION AND MANAGEMENT

Proper routing, sloping, and disposal of condensate.

VENTING CONFIGURATION CAUTIONS

Cautions regarding condensate traps and external vent tees.

CONDENSATE DRAIN TERMINATION

Proper termination of condensate drain lines, including sump pump use.

CONDENSATE DRAIN FREEZING WARNING

Warnings and recommendations to prevent drain line freezing.

SECTION VII: COMBUSTION AIR AND VENT SYSTEM

COMBUSTION AIR AND VENT SAFETY

Safety precautions for combustion air and vent system installations.

VENT SYSTEM INSTALLATION IMPORTANT NOTES

Key information regarding vent system installation for specific home types.

COMBUSTION AIR AND VENT PIPE SIZING

Rules and tables for sizing combustion air and vent piping.

POLYPROPYLENE VENT;INTAKE PIPING

Approved polypropylene piping materials and manufacturers.

COMBUSTION AIR;VENT PIPING ASSEMBLY

Step-by-step procedure for assembling the combustion air and vent piping.

VENT CLEARANCES

DIRECT VENT TERMINAL CLEARANCES

Required clearances for direct vent terminals from various building elements.

VENT SYSTEM CONFIGURATIONS

Information on horizontal and vertical vent system installation options.

VENT APPLICATIONS AND TERMINATION

Guidelines for selecting vent termination locations and considerations.

INTAKE PIPE CONDENSATION WARNING

Warning and solutions for condensation issues in intake pipes.

COMBUSTION AIR SUPPLY

OUTDOOR COMBUSTION AIR

Requirements for bringing combustion air from outdoors via PVC/ABS pipe.

AMBIENT COMBUSTION AIR

Using surrounding space air for combustion, without direct piping.

VENTILATED COMBUSTION AIR

Using air from ventilated attics or crawl spaces via pipe.

COMBUSTION AIR REQUIREMENTS FOR SPACES

Guidelines for unconfined and confined spaces for air supply.

DAMPERS, LOUVERS, AND GRILLES

Considerations for free area calculations involving dampers and grilles.

AIR SUPPLY OPENINGS AND DUCTS

Requirements for air supply openings and duct materials.

COMBUSTION AIR SOURCE FROM OUTDOORS

Methods for supplying combustion air from outdoor spaces.

VENTILATED COMBUSTION AIR TERMINATION

Procedures for terminating ventilated combustion air intake.

SECTION VIII: START-UP AND ADJUSTMENTS

MANDATORY START-UP CHECKS

Essential checks required before operating the furnace for the first time.

ELECTRICAL CONNECTION CHECK

Importance of checking electrical connections for tightness.

GAS PIPING LEAK CHECK

Procedure for checking gas piping for leaks using a soap solution.

CALCULATING FURNACE INPUT

How to calculate the natural gas input rate for the furnace.

MANIFOLD GAS PRESSURE ADJUSTMENT

Steps for adjusting manifold gas pressure to the correct setting.

ADJUSTMENTS AND DIAGNOSTICS

TEMPERATURE RISE ADJUSTMENT

How to adjust blower speed to achieve the correct temperature rise.

FAN CONTROL SETTINGS

Adjusting fan off-delay settings and continuous fan operation.

TAKING A FLUE GAS SAMPLE

Procedure for safely taking flue gas samples for analysis.

SECTION IX: SAFETY CONTROLS

CONTROL CIRCUIT FUSE

Location and purpose of the control circuit fuse.

BLOWER DOOR SAFETY SWITCH

Function and importance of the blower door interlock switch.

SECTION X: NORMAL OPERATION AND DIAGNOSTICS

PRESSURE SWITCHES

Function of pressure switches in monitoring piping and system flow.

LIMIT CONTROLS

Role of the high temperature limit control for airflow protection.

NORMAL OPERATION SEQUENCE

Step-by-step description of furnace operation cycles.

FURNACE CONTROL DIAGNOSTICS

How to interpret control board LED flashes for fault codes.

IGNITION CONTROL FLAME SENSE LEVELS

Parameters for flame sensing and lockout points.

DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

How to retrieve and clear stored diagnostic fault codes.

SECTION XI: REPLACEMENT PARTS LIST

REPLACEMENT PART CONTACT INFORMATION

Information on how to obtain replacement parts and contact the manufacturer.

SECTION XII: WIRING DIAGRAM

WIRING DIAGRAM

Schematic showing electrical connections for the furnace.

FAULT CODE RETRIEVAL

Procedure for retrieving and clearing fault codes from the control board.

SECTION XIII: START UP SHEET

START UP SHEET CONTENT

Checklist for furnace start-up procedures and owner information.