EasyManua.ls Logo

Johnson Controls TM8E - User Manual

Johnson Controls TM8E
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Johnson Controls Ducted Systems 5594752-UIM-C-1119
SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MODELS: TM8E, TMLE
(80% Multi-Position/Standard & Low NOx)
INSTALLATION MANUAL
LIST OF SECTIONS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TWINNING AND STAGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
VENT SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . .16
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . .25
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
LIST OF FIGURES
Duct Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Furnace and Coil Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Combustible Floor Base Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Horizontal Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Suspended Furnace / Crawl Space Installation . . . . . . . . . . . 7
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Side Return Cutout Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Thermostat Chart - Single Stage AC with Single Stage Furnaces . .12
Thermostat Chart - Single Stage HP with Single Stage Furnaces . .12
Twinned Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Combustion Air Inducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Combustion Airflow Path Through The
Furnace Casing to the Burner Compartment . . . . . . . . . . . . . . . . . .14
Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LIST OF TABLES
Unit Clearances to Combustibles (All Dimensions in Inches and cm, and
All Surfaces Identified with the Unit in an Upflow Configuration) . . . . 4
Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Recommended Filter Sizes (High Velocity 600 FPM) . . . . . . . . . . . . 8
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . 11
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . . . .14
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Gas Rate (CU FT/HR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Default Blower Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Blower Performance CFM - Any Position (without filter) . . . . . . . . . .21
These high efficiency, compact units employ induced combustion, reli-
able hot surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in upflow or
horizontal applications and may be converted for downflow applica-
tions.
These furnaces are designed for residential installation in a basement,
closet, alcove, attic, recreation room or garage and are also ideal for
commercial applications. All units are factory assembled, wired and
tested to assure safe dependable and economical installation and oper-
ation.
These units are Category I listed and may be common vented with
another gas appliance as allowed by the National Fuel Gas Code.
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided,
will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided
may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Failure to carefully read and
follow all instructions in this manual can result in furnace mal-
function, death, personal injury and/or property damage. Only a
qualified contractor, installer or service agency should install this
product.
!
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls TM8E and is the answer not in the manual?

Johnson Controls TM8E Specifications

General IconGeneral
ModelTM8E
Efficiency Rating80% AFUE
StagesSingle-Stage
Efficiency80% AFUE
Heating Capacity40, 000-120, 000 BTU/hr
Fuel TypeNatural Gas
Warranty10-Year Parts
CompatibilityCompatible with standard thermostats
ProgrammingNon-Programmable
Backup BatteryNot Applicable

Summary

SAFETY

SECTION I: SAFETY

General safety alerts and warnings about potential hazards.

WARNING (Improper Installation)

Improper installation can cause injury or property damage; read instructions carefully.

SPECIFIC SAFETY RULES AND PRECAUTIONS

SAFETY REQUIREMENTS

COMBUSTION AIR QUALITY

CODES AND STANDARDS

MASSACHUSETTS INSTALLATION REQUIREMENTS

FURNACE LOCATION AND CLEARANCES

DUCTWORK GENERAL INFORMATION

DUCTWORK INSTALLATION - UPFLOW;HORIZONTAL

FLOOR BASE AND DUCTWORK INSTALLATION - DOWNFLOW

COIL INSTALLATION

RESIDENTIAL AND MODULAR HOME UPFLOW RETURN PLENUM CONNECTION

SIDE RETURN APPLICATION

BOTTOM RETURN AND ATTIC INSTALLATIONS

HORIZONTAL APPLICATION

ATTIC INSTALLATION

SUSPENDED FURNACE; CRAWL SPACE INSTALLATION

FILTERS

FILTER INSTALLATION

Instructions for installing filters external to the furnace cabinet.

GAS PIPING

GAS SAFETY

Critical safety warnings regarding gas pressure and handling.

GAS PIPING INSTALLATION

Proper methods for connecting gas piping to the furnace.

GAS ORIFICE CONVERSION FOR PROPANE (LP)

HIGH ALTITUDE GAS ORIFICE CONVERSION

ELECTRICAL POWER

ELECTRICAL POWER CONNECTIONS

Field wiring and connection guidelines for electrical power.

LOW VOLTAGE CONTROL WIRING CONNECTIONS

Instructions for connecting thermostat and control wiring.

ACCESSORY CONNECTIONS

TWINNING AND STAGING

VENT SYSTEM

VENT CONNECTIONS

Guidelines for connecting the vent transition and flue.

VENTING INTO AN EXISTING CHIMNEY

Rules for connecting the furnace to existing chimneys.

FAN-ASSISTED COMBUSTION SYSTEM

Information on the furnace's combustion air system.

Combustion Air Source from Outdoors

Ventilated Combustion Air

Vent and Supply (Outside) Air Safety Check Procedure

START-UP AND ADJUSTMENTS

NOx SCREEN REMOVAL (Lo-NOx Models Only)

Instructions for removing NOx screens for propane conversion.

GAS PIPING LEAK CHECK

CALCULATING THE FURNACE INPUT (NATURAL GAS)

ADJUSTMENT OF MANIFOLD GAS PRESSURE & INPUT RATE

Read the inlet gas pressure

Procedure for measuring inlet gas pressure.

Read the manifold gas pressure

Procedure for measuring manifold gas pressure.

AIRFLOW SETTINGS

Measurement of Temperature Rise

How to measure and adjust temperature rise.

ADJUSTMENT OF FAN CONTROL SETTINGS

Adjusting fan delays and speed settings.

SAFETY CONTROLS

BLOWER DOOR SAFETY SWITCH

Information on the interlock switch for the blower compartment.

ROLLOUT SWITCH CONTROLS

Function and reset procedure for rollout safety switches.

SEQUENCE OF OPERATION

TROUBLESHOOTING

Basic visual checks and troubleshooting steps.

FURNACE CONTROL DIAGNOSTICS

Explanation of diagnostic fault codes and LED indicators.

REPLACEMENT PARTS LIST

REPLACEMENT PART CONTACT INFORMATION

How to obtain a complete parts list and contact customer service.

WIRING DIAGRAM

Fault Code Retrieval

Procedure for retrieving stored diagnostic fault codes.

START UP SHEET

Furnace Configuration

Options for furnace installation orientation (upflow, downflow, etc.).

Venting: B Vent

Details for B Vent type installations, including pipe size and elbows.

Electrical: Line Voltage

Checks for correct line voltage connections and polarity.