5594752-UIM-C-1119
8 Johnson Controls Ducted Systems
SECTION III: FILTERS
FILTER INSTALLATION
All applications require the use of a field installed filter. All filters and
mounting provision must be field supplied.
Filters must be installed external to the furnace cabinet.
DO NOT
attempt to install filters inside the furnace.
1. Air velocity through throwaway type filters may not exceed 300 feet per min-
ute (91.4 m/min). All velocities over this require the use of high velocity fil-
ters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
FIGURE 7: Dimensions
/()76,'(
5,*+76,'(
´
´
5(7851(1'
%
´
´
´
(OHFWULFDO
(QWU\
*DV3LSH
(QWU\
7KHUPRVWDW
:LULQJ
)5217
´
´
´
´
6833/<(1'
&
´
´
´
%
*DV3LSH
(QWU\
7KHUPRVWDW
:LULQJ
´
$
´
(OHFWULFDO
(QWU\
9HQW&RQQHFWLRQ
2XWOHW
9HQW
&RQQHFWLRQ
2XWOHW
´'LDPHWHU
9HQW&RQQHFWLRQ
2XWOHW
$
Table 2: Cabinet and Duct Dimensions
BTUH (kW)
Input
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
Approximate
Operating Weights
A A (cm) B B (cm) C C (cm) Lbs
40 (11.7) 1200 (34.0) A 14 1/2 36.8 13 3/8 34.0 10.3 26.2 89
60 (17.6) 1200 (34.0) A 14 1/2 36.8 13 3/8 34.0 10.3 26.2 94
80 (23.4) 1200 (34.0) B 17 1/2 44.4 16 3/8 41.6 11.8 29.9 103
80 (23.4) 1600 (45.3) C 21 53.3 19 7/8 50.5 13.6 34.5 116
80 (23.4) 2000 (56.6) C 21 53.3 19 7/8 50.5 13.6 34.5 121
100 (29.3) 1200 (34.0) B 17 1/2 44.4 16 3/8 41.6 11.8 29.9 108
100 (29.3) 1600 (45.3) C 21 53.3 19 7/8 50.5 13.6 34.5 120
100 (29.3) 2000 (56.6) C 21 53.3 19 7/8 50.5 13.6 34.5 124
120 (35.1) 1600 (45.3) C 21 53.3 19 7/8 50.5 15.8 40.1 125
120 (35.1) 2000 (56.6) C 21 53.3 19 7/8 50.5 15.8 40.1 131
130 (38.1) 2000 (56.6) D 24.5 62.2 23 3/8 59.4 17.5 44.4 137
CAUTION
All filters and mounting provision must be field supplied. All installa-
tions must have a filter installed.
NOTICE
Single side return above 1800 CFM is approved as long as the filter
velocity does not exceed filter manufacturer’s recommendation.
!
Table 3: Recommended Filter Sizes (High Velocity 600 FPM)
CFM
(m³/min)
Cabinet
Size
Side
(in)
Bottom
(in)
1200 (34.0) A 16 x 25 14 x 25
1200 (34.0) B 16 x 25 16 x 25
1600 (45.3) C 16 x 25 20 x 25
2000 (56.6) C (2) 16 x 25 20 x 25
2000 (56.6) D (2) 16 x 25 22 x 25