©2010 Johnson Level & Tool - Rev. 1 17
Use a 2.5 Metric Hex Key to remove the X vial screw in the X
level vial calibration aperture. Then using the 2.5 Metric Hex
Key, adjust the vial bubble to the middle of the vial as shown
below. Repeat the same procedure for the Y vial.
2.5 Metric Hex Key
Y Level Vial
Y Level Vial
Calibrating Aperture
X Level Vial
Calibrating Aperture
X Level Vial
3919H_Manuals 10/12/10 10:31 AM Page 17