EasyManua.ls Logo

Jolly LX-740 - Display Control and Navigation; Menu Navigation Instructions; Display Operation and Software Version; Error Code Troubleshooting Guide

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.Display control
7.1 Navigation in the Menu
7.2 Display Operation
Using the buttons or touch screen, and this can be simply and easily set the address code and
code.
functions
If you view or modify the lighting feature set, then press ENTER button, the display will enter the menu
interface. Both there is sub menu corresponding to the functional operation of the main menu. Each of the
menus is representative of the specific features of the lamp. The specific contents shows as the table
menu below.
Set or browse lighting function, press UP or DOWN button.
Press ENTER to save your changes or enter the submenu.Press the UP or DOWN can change the nume-
rical (increase or decrease in value).
Press the MODE button to return to menu. Set a time 0 to 10 minutes automatically exit menu interface
and close the screen.
Put through power supply, open the power switch of lamps and lanterns, display show the company
website. According to the main interface, as shown in figure:
In the main interface, press "MODE" button to view the software version, press the "UP" "DOWN" can m-
odify the DMX address.
LOGO
- 9 -
Click on the main interface of the icon, numerical to view view Settings related information of lamps and
lanterns.Symbols such as the main interface appear “ “,the following error message indicates that there
might be a lamps and lanterns,can click to view and control information content to modify the lamps and
lanterns.
CODE #
ERRO INFO CHECK MEASURMENT NOTE
E02 Program Err 1 Check the welding of Chip
E04 MBDInit Error Check the communication signal 485& 485 chip & memory IC
E05 BD1Init Error
E06 BD2Init Error
E12 Bus1 Error Check main cable ABAB(485) chip
E16 MFpga Error
E17 BD1 BUS Error
E18 BD2 BUS Error
E21 Pan FB. Error
E23 Tilt FB. Error
E22 Pan Zero Error
E24 Tilt Zero Error
E36 Zoom RT. Error
E46 H.Fan Error Check the fan of head
E057 EthMDL Error Check the fan of ArtNet、communication signal
RESET
ERROR
Check main cable ABAB(485) chip
Check the communication signal& welding of communication chip
Check the light coupling line, optical coupling switch and a plate of the
relative position measurement
Check cable of sensor, distance and location of ,magnets and sensor