E83 E99 occurred during emptying function.
E84 E99 occurred during filling of water to level.
E85 E99 occurred during filling of water to remove pressure.
E86 Timeout on 'remove pressure' during initialization.
E87 Timeout on emptying during initialization.
E88 Timeout on 'remove pressure' during pre-cooling.
E89 Tilt-switch is not activated even tough the key for Tilt has been pressed for more
than 5 seconds.
E90 The level sensor has detected a low water level in the kettle with a closed system.
Add more water.
E91 The level sensor has detected a low water level. Filling with water for the maximum
permitted time has not produced a normal water level.
Check the water supply to the machine and the strainer, solenoid valve, hoses and
level sensor.
E95 Error in internal memory. Execute item 8.0 in the user menu.
E96 Software error.
Isolate the power to the kettle for 10 seconds and try again.
E97 Software error.
Isolate the power to the kettle for 10 seconds and try again.
E98 Software error.
Isolate the power to the kettle for 10 seconds and try again.
E99 The safety contactor has been disconnected.
This may be due to either the safety temperature limiter or the safety pressure
switch has tripped.
Reset safety temperature limiter (dry-boiling thermostat). Two types are used. See
service manual.
Check the pressure by reading the pressure gauge.
Isolate the power to the kettle until the pressure drops below 0.7 bar and switch the
kettle on again.