Chapter 6 Maintenance and Inspection
96
Error
code
Error
type
Alert indication Alert contents Actions to take
031 CAUTION Time synchronization
failure
The RCU can't receive
the ZDA sentence from
the GPS.
Check the GPS. If the GPS is
working normally, please contact our
head office, or a nearby branch or
local office to request servicing.
041
042
CAUTION OPU* communication
failure
*: 1, 2
The RCU can't
communicate the OPU.
1) Check the cable.
2) Reboot the RCU.
059 INFO Battery expiration date The expiration date of
RCU's built-in battery is
under 1 year.
It is necessary to replace the
underwater acoustic beacon. Please
contact our head office, or a nearby
branch or local office to request
servicing.
060 INFO Fixed capsule beacon
expiration date
The expiration date of
FPC's underwater
acoustic beacon is
under 1 year.
It is necessary to replace the
underwater acoustic beacon. Please
contact our head office, or a nearby
branch or local office to request
servicing.
061 INFO Float-free capsule
battery expiration date
The expiration date of
FFC's built-in battery is
under 1 year.
It is necessary to replace the battery.
Please contact our head office, or a
nearby branch or local office to
request servicing.
062 INFO RCU fan expiration
date
The expiration date of
RCU's built-in fan is
under 1 year.
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
063 to
065
INFO FGU* fan expiration
date
*: 1 to 3
The expiration date of
FGU's built-in fan is
under 1 year.
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
066 INFO Float-free capsule HRU
expiration date
The expiration date of
FFC'S hydrostatic
release unit is under 1
year.
It is necessary to replace the
hydrostatic release unit. Please
contact our head office, or a nearby
branch or local office to request
servicing.
101 CAUTION Fixed capsule short
store period
The FPC's data
recording possible time
has decreased.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few days.
102 WARNING Fixed capsule
connection failure
The RCU can't
communicate with the
FPC.
1) Check the cable.
2) Reboot the RCU.