Chapter 6 Maintenance and Inspection
97
Error
code
Error
type
Alert indication Alert contents Actions to take
103 CAUTION Fixed capsule
recording failure
The FPC can't record
data.
Reboot the RCU.
104 CAUTION Float-free capsule
short store period
The FFC's data
recording possible time
has decreased.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few days.
105 WARNING Float-free capsule
connection failure
The RCU can't
communicate the FFC.
1) Check the cable.
2) Reboot the RCU.
106 CAUTION Float-free capsule
recording failure
The FFC can't record
data.
Reboot the RCU.
107 CAUTION Internal storage short
store period
The data recording
possible time of
internal storage has
decreased.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few weeks.
108
109
WARNING Internal storage (No.*)
access failure
*: 1, 2
The RCU's internal
storage can't access.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
110
111
CAUTION Internal storage (No.*)
recording failure
*: 1, 2
The RCU's internal
storage can't record
data.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
201 to
212
CAUTION Microphone (CH*)
failure
*: 1 to 12
The result of
self-diagnosis test has
a problem.
1) Check the wiring between the
RCU and the microphone.
2) In environment without a loud
noise, retry the self-diagnosis test.
See 4.5.4 Checking the audio
data
221 WARNING ARB initialization
failure
The initialization of the
ARB failed.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
222 WARNING ARB control failure There is no response of
the ARB.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.

Table of Contents

Other manuals for JRC JCY-1900

Related product manuals