1. OUTLINE
JCY-1900
/
1950
V
DR Service Manual
8
DOC No. 7ZPNA4409
1.4. Present and New Model Comparison Table
* In S-VDR, use one of capsules (: NDH-338 or NDH-339).
1) Standard specifications
Item JCY-1900/1950 JCY-1800/1850
Capsule Fixed Protective Capsule Unit
48 hours recording
Protective Capsule Unit
12 hours recording
Float-free Capsule Unit
48 hours recording
None
Internal storage for long term re-
cording
720 hours (30 days) recording
(Unremovable)
CF card
12 hours (half day) recording
Sensor recording LAN: 1 port (IEC61162-450, RMS)
Number of connectable units: 24ch
LAN: 1 port (dedicated for RMS)
Number of connectable units: 24ch
Serial: 24ch
IEC61162-2: 2ch (4800~38400bps)
IEC61162-1: 22ch (4800bps)
Serial: 32ch
(4800~38400bps)
Audio recording Bridge audio (microphone)
6 tracks x 2ch/track = 12ch
(standard)
VHF audio
2 tracks x 2ch/track = 4ch
Bridge audio (microphone)
3 tracks x 3ch/track = 9ch
VHF audio
1 track x 3ch/track = 3ch
Image recording Input signal: LAN(IEC61162-450)
Number of available inputs: 6
screens
Number of screens for recording:
3 screens (standard)
6 screens are se-
lectable for recording.
Input signal: RGB
Number of available inputs: 2
screens
Number of screens for recording:
1 screen (standard)
2 screens are se-
lectable for recording.
Recording both 2 screens
(option)
Electric power failure Operation continues for 2 hours with
UPS.
* Only bridge audio is recorded dur-
ing power failure.
* After power restoration, VDR au-
tomatically returns to the normal
operation.
Same as JCY-1900
Operation Panel Unit Display: LCD (Character display)
Operation: Touch Panel
* Meets the performance test de-
manded.
Display: LEDs (Value display)
Operation: Buttons
Error information: 4-digit code dis-
play
Stopping/restarting
recording
Operation by the Operation Panel
Unit.
Ensures security with a password
Operation by the RCU internal panel.
Performance test Checking the latest recorded data is
available through the Operation
Panel Unit.
None
Microphone test Automatic test is conducted every 12
hours.
Manual test is available with the Op-
eration Panel Unit.
Automatic test is conducted every 12
hours.
Alert output Output port: Dry contact, serial, LAN Output port: Dry contact

Table of Contents